2.0mm Adaption Straight Locking Plate

2.0mm Adaption Straight Locking Plate

2.0mm Adaption Straight Locking Plate in titanium with 12 shaft holes and an 81.26 mm length. Features compression and locking holes and supports 2.0mm cortical and locking screws.

Product Specifications

2.0mm Adaption Straight Locking Plate is a 12-hole titanium plate measuring 81.26 mm. It is listed under reference 4-312-12Ti within the StahlmannPro 2.0mm Hand System.

The design includes compression and locking holes, with support for 2.0mm cortical and locking screws in all holes. The catalogue describes bending in two directions and twisting for adaptation to small bones. Contouring must follow the applicable product instructions; specific bending limits are not provided in the supplied page.

Specifications

  • Titanium construction.
  • 12 shaft holes.
  • 81.26 mm length.
  • Compression and locking holes.
  • All holes support 2.0mm cortical and locking screws.

Catalogue Applications

The listed applications are non-comminuted, wedge-comminuted and comminuted diaphyseal fractures of the hand phalanges. The treating surgical team determines the appropriate configuration and use.

Sizes and Product References

Holes Length (mm) Titanium
12 81.26 4-312-12Ti

Ordering Information

Quote 4-312-12Ti and the required quantity. This 81.26 mm model is distinct from the 71 mm Adaption Straight Plate, reference 4-316-12Ti. Include the full product name and length to avoid confusing the two 12-hole products.

FAQs

What are its dimensions and hole count?

The listed titanium plate has 12 shaft holes and a length of 81.26 mm. Its catalogue reference is 4-312-12Ti.

Which fractures are described in the catalogue?

The listed applications are non-comminuted, wedge-comminuted and comminuted diaphyseal fractures of hand phalanges. Clinical selection must follow the device instructions.

Can the plate be contoured?

The catalogue describes bending in two directions and twisting for small-bone adaptation. Follow the product instructions and approved instrument requirements for any contouring.

Which screws are supported?

All plate holes are described as supporting 2.0mm cortical and locking screws. The plate also features compression and locking holes.

Is this the same as the 71 mm Adaption Straight Plate?

No. This model measures 81.26 mm and uses 4-312-12Ti. The separate Adaption Straight Plate measures 71 mm and uses 4-316-12Ti, although both have 12 holes.

Request a Quote