2.0mm T Locking Plate in titanium with compression and locking holes. The catalogue table lists four lengths from 32.1 to 52.5 mm. Confirm the hole configuration before ordering because the source wording differs from its table.
2.0mm T Locking Plate is a titanium plate featuring compression and locking holes. Its catalogue table presents four length options: 32.1, 38.9, 45.7 and 52.5 mm, with individual references in the 4-304 series.
The table lists 4, 5, 6 or 7 shaft holes with 3 head holes. A separate specification sentence states 7 shaft holes and 2 head holes. These source statements differ, so the table is reproduced unchanged below and the intended configuration should be confirmed before ordering. All holes are described as supporting 2.0mm cortical and locking screws.
The catalogue lists proximal and distal extra-articular, partial articular and complete articular fractures of hand phalanges. Use should follow the applicable device instructions and clinical assessment.
| Holes | Length (mm) | Titanium |
|---|---|---|
| Shaft 4, Head 3 | 32.1 | 4-304-04Ti |
| Shaft 5, Head 3 | 38.9 | 4-304-05Ti |
| Shaft 6, Head 3 | 45.7 | 4-304-06Ti |
| Shaft 7, Head 3 | 52.5 | 4-304-07Ti |
Provide the reference and length you require, and request written confirmation of the shaft and head hole configuration. Keep this model distinct from the T Adaption Locking Plate, reference 4-302-07Ti.
The table lists 32.1, 38.9, 45.7 and 52.5 mm, with references 4-304-04Ti, 4-304-05Ti, 4-304-06Ti and 4-304-07Ti respectively.
The table lists 4 to 7 shaft holes with 3 head holes, but a specification sentence states 7 shaft and 2 head holes. Confirm the required configuration against current product documentation.
The catalogue describes support for 2.0mm cortical and locking screws in all holes. Confirm the exact plate configuration and system components before use.
It lists proximal and distal extra-articular, partial articular and complete articular fractures of hand phalanges. Clinical suitability depends on the individual case and device instructions.
Include the desired length, table reference and quantity, and ask for confirmation of the shaft and head hole counts because the source contains inconsistent configuration wording.