2.0mm T Adaption Locking Plate in titanium with 7 shaft holes and 2 head holes. Includes compression and locking holes and supports 2.0mm cortical and locking screws.
2.0mm T Adaption Locking Plate is a titanium hand plate with 7 shaft holes and 2 head holes. The catalogue lists one configuration under reference 4-302-07Ti, with compression and locking holes.
This T adaption design is described as allowing bending in two directions and twisting to accommodate small-bone anatomy. The shape and head-hole arrangement distinguish it from the Y Adaption model. The source does not provide an overall plate length, so dimensional requirements should be confirmed using current product documentation.
The catalogue lists proximal and distal extra-articular, partial articular and complete articular fractures of the hand phalanges. Clinical selection and any plate contouring must follow professional assessment and the applicable instructions for use.
| Holes | Titanium |
|---|---|
| Shaft 7, Head 2 | 4-302-07Ti |
Use 4-302-07Ti when enquiring about this model. Include quantity and any requests for overall dimensions or compatible instruments. The T Adaption Locking Plate and T Locking Plate are separate catalogue products.
The catalogue lists proximal and distal extra-articular, partial articular and complete articular fractures of hand phalanges. The treating surgeon determines suitability for the individual case.
This plate has 7 shaft holes and 2 head holes. Its catalogue reference is 4-302-07Ti; the table does not state an overall length.
Yes. All plate holes are described as supporting 2.0mm cortical and locking screws. Confirm the exact system components and instruments before use.
The catalogue describes bending in two directions and twisting for adaptation to small bones. Follow the device instructions for permitted contouring and compatible instruments.
The T Adaption model has a single listed 7-shaft, 2-head configuration. The separate T Locking Plate has multiple table entries and a source discrepancy in its hole-count wording, which requires confirmation.