2.0mm Y Adaption Locking Plate in titanium with 7 shaft holes and 3 head holes. Features compression and locking holes, with support for 2.0mm cortical and locking screws.
2.0mm Y Adaption Locking Plate combines a 7-hole shaft and 3-hole head in a titanium design within the StahlmannPro 2.0mm Hand System. Its Y configuration is listed under one catalogue reference, 4-300-07Ti.
The plate features compression and locking holes. The catalogue describes an adaption design that can be bent in two directions and twisted to accommodate small-bone anatomy. Any contouring must follow the applicable device instructions and instrument requirements. The supplied page does not specify an overall plate length or a separate indication statement.
| Holes | Titanium |
|---|---|
| Shaft 7, Head 3 | 4-300-07Ti |
Quote 4-300-07Ti and the required quantity when requesting this Y plate. If length, contouring limits or intended-use details are essential to your evaluation, request the corresponding product documentation before confirming the order.
The titanium plate has 7 shaft holes and 3 head holes. The catalogue identifies this configuration with reference 4-300-07Ti.
All plate holes are described as supporting 2.0mm cortical and locking screws. Confirm the complete component and instrument requirements for the intended system.
The catalogue describes bending in two directions and twisting to accommodate small bones. Contouring should follow the applicable device instructions; bending limits and instruments are not specified on this page.
The supplied specification table does not state an overall length. Request the current dimensional specification rather than inferring length from the image or hole count.
Provide the product name, reference 4-300-07Ti, quantity and delivery destination. Include any requests for dimensional or intended-use documentation.