2.0mm Adaption Straight Plate in titanium with 12 shaft holes and a 71 mm length. The catalogue describes a contourable adaption design supporting 2.0mm cortical and locking screws.
2.0mm Adaption Straight Plate is a 71 mm titanium plate with 12 shaft holes. Its catalogue reference, 4-316-12Ti, distinguishes it from the separately listed Adaption Straight Locking Plate.
The catalogue describes a design that can be bent in two directions and twisted for adaptation to small bones. All holes support 2.0mm cortical and locking screws. The product title is retained as Adaption Straight Plate, and the source does not explicitly describe compression holes for this model.
The listed applications are non-comminuted, wedge-comminuted and comminuted diaphyseal fractures of hand phalanges. Clinical selection and any contouring must follow the applicable device instructions.
| Holes | Length (mm) | Titanium |
|---|---|---|
| 12 | 71 | 4-316-12Ti |
Quote the full name, 71 mm length and 4-316-12Ti reference with the required quantity. The 81.26 mm Adaption Straight Locking Plate has a different reference and should remain a separate item in purchase enquiries.
The listed plate has 12 shaft holes and a length of 71 mm. It is available in titanium under reference 4-316-12Ti.
It lists non-comminuted, wedge-comminuted and comminuted diaphyseal fractures of hand phalanges. The surgical team determines suitability for the case.
Yes. The source states that all holes support 2.0mm cortical and locking screws. The catalogue product title remains Adaption Straight Plate.
The catalogue describes bending in two directions and twisting for small-bone adaptation. Follow the current device instructions and approved instrumentation for contouring.
This plate is 71 mm long and uses 4-316-12Ti. The separate locking-named model is 81.26 mm long, uses 4-312-12Ti and explicitly lists compression and locking holes.