2.0mm Condylar Locking Plate in titanium with 2 head holes and 4 to 7 shaft holes. Four lengths span 33.6 to 54.0 mm. Confirm the specified screw options against current device documentation.
2.0mm Condylar Locking Plate is offered in four titanium configurations, each with 2 head holes. Shaft options of 4, 5, 6 and 7 holes correspond to lengths of 33.6, 40.4, 47.2 and 54.0 mm.
The plate features compression and locking holes. The specification section states support for 2.0mm cortical and locking screws, while a later line additionally mentions 1.5/2.0mm cortical screws. These statements are retained as a qualification rather than treated as independently verified compatibility for every screw option.
The catalogue lists proximal and distal partial articular fractures of hand phalanges involving the medial or lateral unicondyle. Clinical selection and component compatibility must follow the applicable instructions for use.
| Holes | Length (mm) | Titanium |
|---|---|---|
| Shaft 4, Head 2 | 33.6 | 4-310-04Ti |
| Shaft 5, Head 2 | 40.4 | 4-310-05Ti |
| Shaft 6, Head 2 | 47.2 | 4-310-06Ti |
| Shaft 7, Head 2 | 54.0 | 4-310-07Ti |
Specify the shaft-hole count, length and complete 4-310 product reference. Ask for confirmation of screw diameter and type, especially if requesting the additional 1.5mm cortical option mentioned in the source.
The catalogue lists proximal and distal partial articular fractures of hand phalanges involving the medial or lateral unicondyle. Suitability must be assessed by the treating surgeon.
All options have 2 head holes. The table lists 4 shaft holes at 33.6 mm, 5 at 40.4 mm, 6 at 47.2 mm and 7 at 54.0 mm.
The main specifications state 2.0mm cortical and locking screws. Another line mentions 1.5/2.0mm cortical screws. Confirm the permitted diameter and type in current device documentation before ordering or use.
No. The Condylar Locking Plate has four listed lengths in the 4-310 series. The Mini Condylar Plate is a separate left/right product with 7 holes and a listed overall height of 29mm.
Use 4-310-04Ti, 4-310-05Ti, 4-310-06Ti or 4-310-07Ti for the corresponding shaft-hole count. Include quantity and request confirmation of any additional screw requirements.