2.0mm Rotation Correction Locking Plate in titanium with an elongated transverse shaft hole. Listed in 34 mm and 40 mm lengths, both with 2 head holes and either 4 or 5 shaft holes.
2.0mm Rotation Correction Locking Plate is a titanium plate offered in two shaft configurations. The 34 mm option has 4 shaft holes and 2 head holes, while the 40 mm option has 5 shaft holes and 2 head holes.
The catalogue describes compression and locking holes, a low plate and screw profile, rounded edges and polished surfaces. Its elongated transverse shaft hole is described as allowing intraoperative inspection of reduction and correction of the bone’s rotational axis when necessary. These are device features, not a guarantee of a clinical outcome.
The catalogue lists fixation of fractures, osteotomies, nonunions, replantations and fusion of small bone fragments, particularly in osteopenic bones. It also describes the two shaft lengths in relation to metacarpal and proximal phalangeal fractures. Confirm the exact indication and component requirements in the current instructions for use.
| Holes | Length (mm) | Titanium |
|---|---|---|
| Shaft 4, Head 2 | 34 | 4-306-04Ti |
| Shaft 5, Head 2 | 40 | 4-306-05Ti |
Specify 4-306-04Ti for the 34 mm plate or 4-306-05Ti for the 40 mm plate. This source page does not explicitly list screw compatibility; request confirmation for the selected configuration.
The catalogue describes an elongated transverse shaft hole for intraoperative inspection of reduction and rotational-axis correction when needed. Its use must follow the applicable device instructions.
The 34 mm plate has 4 shaft and 2 head holes, reference 4-306-04Ti. The 40 mm plate has 5 shaft and 2 head holes, reference 4-306-05Ti.
The plate is titanium. The catalogue describes a low plate and screw profile, rounded edges, polished surfaces, and compression and locking holes.
The catalogue lists fractures, osteotomies, nonunions, replantations and fusion of small bone fragments, particularly in osteopenic bones. Confirm patient-specific suitability and the current instructions for use.
The supplied page does not explicitly state screw compatibility. Request the approved screw and instrument specification for the chosen plate rather than inferring compatibility from its 2.0mm name.