Specification
• Cannulated shaft accepts guide wires of 2.0mm
• Hemispherical head of the screws ensures optimal annular contact with washers and
plates when screws are angled
• Low-profile head reduces possibility of soft tissue irritation
• Standard 3.5mm hexagonal drive is compatible
• Reverse cutting flutes assist in screw
• Choice of thread lengths offers best fit of threads into far bone fragment, for greater
interfragmentary compression
• Thread Length- 16mm thread
• Cancellous thread profile uses deep ‘cutting threads’ with a large pitch to increase
resistance to pullout. The large pitch also accelerates screw insertion and removal.
• Length ranges from 50mm-120mm with a diameter of 7.0mm.
• Available in both Titanium and Stainless Steel
Indications for use
Fixation of fractures with large fragments, eg.-
• Femoral neck fractures
• Intercondylar femoral fractures
• Epiphyseolysis of the femoral head
• Ankle arthrodeses
• Iliosacral dislocations
Specification
• Cannulated shaft accepts guide wires of 2.0mm
• Hemispherical head of the screws ensures optimal annular contact with washers and
plates when screws are angled
• Low-profile head reduces possibility of soft tissue irritation
• Standard 3.5mm hexagonal drive is compatible
• Reverse cutting flutes assist in screw
• Choice of thread lengths offers best fit of threads into far bone fragment, for greater
interfragmentary compression
• Thread Length- 16mm thread
• Cancellous thread profile uses deep ‘cutting threads’ with a large pitch to increase
resistance to pullout. The large pitch also accelerates screw insertion and removal.
• Length ranges from 50mm-120mm with a diameter of 7.0mm.
• Available in both Titanium and Stainless Steel
Indications for use
Fixation of fractures with large fragments, eg.-
• Femoral neck fractures
• Intercondylar femoral fractures
• Epiphyseolysis of the femoral head
• Ankle arthrodeses
• Iliosacral dislocations
| Length (mm) | Stainless Steel | Titanium |
|---|---|---|
| 30 | 7-250-30 | 7-250-30Ti |
| 35 | 7-250-35 | 7-250-35Ti |
| 40 | 7-250-40 | 7-250-40Ti |
| 45 | 7-250-45 | 7-250-45Ti |
| 50 | 7-250-50 | 7-250-50Ti |
| 55 | 7-250-55 | 7-250-55Ti |
| 60 | 7-250-60 | 7-250-60Ti |
| 65 | 7-250-65 | 7-250-65Ti |
| 70 | 7-250-70 | 7-250-70Ti |
| 75 | 7-250-75 | 7-250-75Ti |
| 80 | 7-250-80 | 7-250-80Ti |
| 85 | 7-250-85 | 7-250-85Ti |
| 90 | 7-250-90 | 7-250-90Ti |
| 95 | 7-250-95 | 7-250-95Ti |
| 100 | 7-250-100 | 7-250-100Ti |
| 105 | 7-250-105 | 7-250-105Ti |
| 110 | 7-250-110 | 7-250-110Ti |
| 115 | 7-250-115 | 7-250-115Ti |
| 120 | 7-250-120 | 7-250-120Ti |
| Length (mm) | Stainless Steel | Titanium |
|---|---|---|
| 35 | 7-260-35 | 7-260-35Ti |
| 40 | 7-260-40 | 7-260-40Ti |
| 45 | 7-260-45 | 7-260-45Ti |
| 50 | 7-260-50 | 7-260-50Ti |
| 55 | 7-260-55 | 7-260-55Ti |
| 60 | 7-260-60 | 7-260-60Ti |
| 65 | 7-260-65 | 7-260-65Ti |
| 70 | 7-260-70 | 7-260-70Ti |
| 75 | 7-260-75 | 7-260-75Ti |
| 80 | 7-260-80 | 7-260-80Ti |
| 85 | 7-260-85 | 7-260-85Ti |
| 90 | 7-260-90 | 7-260-90Ti |
| 95 | 7-260-95 | 7-260-95Ti |
| 100 | 7-260-100 | 7-260-100Ti |
| 105 | 7-260-105 | 7-260-105Ti |
| 110 | 7-260-110 | 7-260-110Ti |
| 115 | 7-260-115 | 7-260-115Ti |
| 120 | 7-260-120 | 7-260-120Ti |
| Length (mm) | Stainless Steel | Titanium |
|---|---|---|
| 30 | 7-270-30 | 7-270-30Ti |
| 35 | 7-270-35 | 7-270-35Ti |
| 40 | 7-270-40 | 7-270-40Ti |
| 45 | 7-270-45 | 7-270-45Ti |
| 50 | 7-270-50 | 7-270-50Ti |
| 55 | 7-270-55 | 7-270-55Ti |
| 60 | 7-270-60 | 7-270-60Ti |
| 65 | 7-270-65 | 7-270-65Ti |
| 70 | 7-270-70 | 7-270-70Ti |
| 75 | 7-270-75 | 7-270-75Ti |
| 80 | 7-270-80 | 7-270-80Ti |
| 85 | 7-270-85 | 7-270-85Ti |
| 90 | 7-270-90 | 7-270-90Ti |
| 95 | 7-270-95 | 7-270-95Ti |
| 100 | 7-270-100 | 7-270-100Ti |
| 105 | 7-270-105 | 7-270-105Ti |
| 110 | 7-270-110 | 7-270-110Ti |
| 115 | 7-270-115 | 7-270-115Ti |
| 120 | 7-270-120 | 7-270-120Ti |
StahlmannPro offers a comprehensive range of orthopedic and medical solutions, including trauma implants, spine implants, craniomaxillofacial systems, arthroplasty solutions, sports medicine products, surgical instruments, and power tools.
Yes. StahlmannPro serves hospitals, surgeons, healthcare professionals, and medical distributors with orthopedic implant and surgical solutions for international markets.