WHX Miami 2026 "June 17–19, 2026 Miami Beach Convention Center, USA"

EUROSPINE 2026 "October 7–9, 2026 Gothia Towers & Svenska Mässan, Gothenburg, Sweden"

MEDICA 2026 "November 16–19, 2026 Messe Düsseldorf, Germany"

WHX Dubai 2027 "January 25–28, 2027 Dubai Exhibition Centre, UAE"

AAOS 2027 "March 3–6, 2027 Venetian Convention & Expo Center, Las Vegas, Nevada, USA"

4.0mm Cannulated Cancellous Screw

4.0mm Cannulated Cancellous Screw

The 4.0mm Cannulated Cancellous Screw is an orthopedic fixation screw for medium-fragment fractures and selected foot osteotomies and arthrodeses. Available in titanium and stainless steel, it accepts a 1.2mm guide wire and uses a standard 2.5mm hexagonal drive.

Real-World Performance & Utility

The cannulated shaft allows insertion over a 1.2mm guide wire, guiding the screw along the selected trajectory. Its 2.5mm hexagonal drive provides compatibility with a matching driver.

The hemispherical head supports annular contact with washers and plates when the screw is angled. A low-profile head helps reduce the possibility of soft tissue irritation around the fixation site.

Thread length matters when interfragmentary compression is required. Selecting a threaded portion that fits within the far bone fragment supports compression across the fracture. Fully threaded screws are intended for stabilization where little or no compression is needed.

Deep cancellous cutting threads with a large pitch increase resistance to pullout. The large pitch also supports faster insertion and removal.

Listed applications include tarsal and metatarsal fractures, metatarsal and phalangeal osteotomies, tarsometatarsal and metatarsophalangeal arthrodeses, ligament fixation, and hallux valgus correction.

Product Specifications

The 4.0mm Cannulated Cancellous Screw is an orthopedic fixation screw for medium-fragment fractures and selected foot osteotomies and arthrodeses. Available in titanium and stainless steel, it accepts a 1.2mm guide wire and uses a standard 2.5mm hexagonal drive.

Real-World Performance & Utility

The cannulated shaft allows insertion over a 1.2mm guide wire, guiding the screw along the selected trajectory. Its 2.5mm hexagonal drive provides compatibility with a matching driver.

The hemispherical head supports annular contact with washers and plates when the screw is angled. A low-profile head helps reduce the possibility of soft tissue irritation around the fixation site.

Thread length matters when interfragmentary compression is required. Selecting a threaded portion that fits within the far bone fragment supports compression across the fracture. Fully threaded screws are intended for stabilization where little or no compression is needed.

Deep cancellous cutting threads with a large pitch increase resistance to pullout. The large pitch also supports faster insertion and removal.

Listed applications include tarsal and metatarsal fractures, metatarsal and phalangeal osteotomies, tarsometatarsal and metatarsophalangeal arthrodeses, ligament fixation, and hallux valgus correction.

Technical Specifications & Core Capabilities

  • Screw diameter: 4.0mm.
  • Guide wire compatibility: 1.2mm.
  • Drive size: Standard 2.5mm hexagonal drive.
  • Materials: Titanium and stainless steel.
  • Head geometry: Hemispherical head for annular contact with washers and plates during angled placement.
  • Head profile: Low profile to help reduce soft tissue irritation.
  • Thread profile: Deep cancellous cutting threads with a large pitch.
  • Short-thread proportion: Described in the supplied specifications as one-third of the screw length.
  • Long-thread proportion: Described in the supplied specifications as one-half of the screw length.
  • Screenshot configurations: Short thread self-tapping and full thread self-tapping.
  • Catalogue screw lengths: 10–50mm in 2mm increments, followed by 55, 60, 65 and 70mm.
  • Fully threaded screw purpose: Stabilization where little or no compression across the fracture site is required.
  • Listed indications: Tarsal and metatarsal fractures; metatarsal and phalangeal osteotomies; tarsometatarsal and metatarsophalangeal arthrodeses; ligament fixation; hallux valgus correction.
4.0mm Cannulated Cancellous Screws, Short Thread, Self-Tapping
Length (mm) Stainless Steel Titanium
10 7-160-10 7-160-10Ti
12 7-160-12 7-160-12Ti
14 7-160-14 7-160-14Ti
16 7-160-16 7-160-16Ti
18 7-160-18 7-160-18Ti
20 7-160-20 7-160-20Ti
22 7-160-22 7-160-22Ti
24 7-160-24 7-160-24Ti
26 7-160-26 7-160-26Ti
28 7-160-28 7-160-28Ti
30 7-160-30 7-160-30Ti
32 7-160-32 7-160-32Ti
34 7-160-34 7-160-34Ti
36 7-160-36 7-160-36Ti
38 7-160-38 7-160-38Ti
40 7-160-40 7-160-40Ti
42 7-160-42 7-160-42Ti
44 7-160-44 7-160-44Ti
46 7-160-46 7-160-46Ti
48 7-160-48 7-160-48Ti
50 7-160-50 7-160-50Ti
55 7-160-55 7-160-55Ti
60 7-160-60 7-160-60Ti
65 7-160-65 7-160-65Ti
70 7-160-70 7-160-70Ti
4.0mm Cannulated Cancellous Screws, Full Thread, Self-Tapping
Length (mm) Stainless Steel Titanium
10 7-170-10 7-170-10Ti
12 7-170-12 7-170-12Ti
14 7-170-14 7-170-14Ti
16 7-170-16 7-170-16Ti
18 7-170-18 7-170-18Ti
20 7-170-20 7-170-20Ti
22 7-170-22 7-170-22Ti
24 7-170-24 7-170-24Ti
26 7-170-26 7-170-26Ti
28 7-170-28 7-170-28Ti
30 7-170-30 7-170-30Ti
32 7-170-32 7-170-32Ti
34 7-170-34 7-170-34Ti
36 7-170-36 7-170-36Ti
38 7-170-38 7-170-38Ti
40 7-170-40 7-170-40Ti
42 7-170-42 7-170-42Ti
44 7-170-44 7-170-44Ti
46 7-170-46 7-170-46Ti
48 7-170-48 7-170-48Ti
50 7-170-50 7-170-50Ti
55 7-170-55 7-170-55Ti
60 7-170-60 7-170-60Ti
65 7-170-65 7-170-65Ti
70 7-170-70 7-170-70Ti

FAQs

What guide wire and screwdriver fit the 4.0mm Cannulated Cancellous Screw?

The screw accepts a 1.2mm guide wire and uses a standard 2.5mm hexagonal drive.

What sizes and materials are listed in the catalogue?

Both screenshot tables list titanium and stainless steel screws in 10–50mm lengths at 2mm increments, followed by 55, 60, 65 and 70mm.

What is the difference between short-thread and fully threaded screws?

Short-thread screws support interfragmentary compression when their threads engage the far bone fragment. Fully threaded screws are intended to stabilize fractures where little or no compression is needed.

Request a Quote

Related products

Request a Quote

WhatsApp Chat