WHX Miami 2026 "June 17–19, 2026 Miami Beach Convention Center, USA"

EUROSPINE 2026 "October 7–9, 2026 Gothia Towers & Svenska Mässan, Gothenburg, Sweden"

MEDICA 2026 "November 16–19, 2026 Messe Düsseldorf, Germany"

WHX Dubai 2027 "January 25–28, 2027 Dubai Exhibition Centre, UAE"

AAOS 2027 "March 3–6, 2027 Venetian Convention & Expo Center, Las Vegas, Nevada, USA"

AUTO-DRAFT (Copy) (Copy)

AUTO-DRAFT (Copy) (Copy)

Specification
• Cannulated shaft accepts guide wires of 2.0mm
• Hemispherical head of the screws ensures optimal annular contact with washers and
plates when screws are angled
• Low-profile head reduces possibility of soft tissue irritation
• Standard 3.5mm hexagonal drive is compatible
• Reverse cutting flutes assist in screw
• Choice of thread lengths offers best fit of threads into far bone fragment, for greater
interfragmentary compression
• Thread Length- 16mm thread
• Cancellous thread profile uses deep ‘cutting threads’ with a large pitch to increase
resistance to pullout. The large pitch also accelerates screw insertion and removal.
• Length ranges from 50mm-120mm with a diameter of 7.0mm.
• Available in both Titanium and Stainless Steel
Indications for use
Fixation of fractures with large fragments, eg.-
• Femoral neck fractures
• Intercondylar femoral fractures
• Epiphyseolysis of the femoral head
• Ankle arthrodeses
• Iliosacral dislocations

Product Specifications

Specification
• Cannulated shaft accepts guide wires of 2.0mm
• Hemispherical head of the screws ensures optimal annular contact with washers and
plates when screws are angled
• Low-profile head reduces possibility of soft tissue irritation
• Standard 3.5mm hexagonal drive is compatible
• Reverse cutting flutes assist in screw
• Choice of thread lengths offers best fit of threads into far bone fragment, for greater
interfragmentary compression
• Thread Length- 16mm thread
• Cancellous thread profile uses deep ‘cutting threads’ with a large pitch to increase
resistance to pullout. The large pitch also accelerates screw insertion and removal.
• Length ranges from 50mm-120mm with a diameter of 7.0mm.
• Available in both Titanium and Stainless Steel
Indications for use
Fixation of fractures with large fragments, eg.-
• Femoral neck fractures
• Intercondylar femoral fractures
• Epiphyseolysis of the femoral head
• Ankle arthrodeses
• Iliosacral dislocations

7.0mm Cannulated Cancellous Screws, 16mm Thread, Self-Drilling

Length (mm) Stainless Steel Titanium
30 7-250-30 7-250-30Ti
35 7-250-35 7-250-35Ti
40 7-250-40 7-250-40Ti
45 7-250-45 7-250-45Ti
50 7-250-50 7-250-50Ti
55 7-250-55 7-250-55Ti
60 7-250-60 7-250-60Ti
65 7-250-65 7-250-65Ti
70 7-250-70 7-250-70Ti
75 7-250-75 7-250-75Ti
80 7-250-80 7-250-80Ti
85 7-250-85 7-250-85Ti
90 7-250-90 7-250-90Ti
95 7-250-95 7-250-95Ti
100 7-250-100 7-250-100Ti
105 7-250-105 7-250-105Ti
110 7-250-110 7-250-110Ti
115 7-250-115 7-250-115Ti
120 7-250-120 7-250-120Ti

7.0mm Cannulated Cancellous Screws, 32mm Thread, Self-Drilling

Length (mm) Stainless Steel Titanium
35 7-260-35 7-260-35Ti
40 7-260-40 7-260-40Ti
45 7-260-45 7-260-45Ti
50 7-260-50 7-260-50Ti
55 7-260-55 7-260-55Ti
60 7-260-60 7-260-60Ti
65 7-260-65 7-260-65Ti
70 7-260-70 7-260-70Ti
75 7-260-75 7-260-75Ti
80 7-260-80 7-260-80Ti
85 7-260-85 7-260-85Ti
90 7-260-90 7-260-90Ti
95 7-260-95 7-260-95Ti
100 7-260-100 7-260-100Ti
105 7-260-105 7-260-105Ti
110 7-260-110 7-260-110Ti
115 7-260-115 7-260-115Ti
120 7-260-120 7-260-120Ti

7.0mm Cannulated Cancellous Screws, Full Thread, Self-Drilling

Length (mm) Stainless Steel Titanium
30 7-270-30 7-270-30Ti
35 7-270-35 7-270-35Ti
40 7-270-40 7-270-40Ti
45 7-270-45 7-270-45Ti
50 7-270-50 7-270-50Ti
55 7-270-55 7-270-55Ti
60 7-270-60 7-270-60Ti
65 7-270-65 7-270-65Ti
70 7-270-70 7-270-70Ti
75 7-270-75 7-270-75Ti
80 7-270-80 7-270-80Ti
85 7-270-85 7-270-85Ti
90 7-270-90 7-270-90Ti
95 7-270-95 7-270-95Ti
100 7-270-100 7-270-100Ti
105 7-270-105 7-270-105Ti
110 7-270-110 7-270-110Ti
115 7-270-115 7-270-115Ti
120 7-270-120 7-270-120Ti

 

Related products

Request a Quote

WhatsApp Chat