WHX Miami 2026 "June 17–19, 2026 Miami Beach Convention Center, USA"

EUROSPINE 2026 "October 7–9, 2026 Gothia Towers & Svenska Mässan, Gothenburg, Sweden"

MEDICA 2026 "November 16–19, 2026 Messe Düsseldorf, Germany"

WHX Dubai 2027 "January 25–28, 2027 Dubai Exhibition Centre, UAE"

AAOS 2027 "March 3–6, 2027 Venetian Convention & Expo Center, Las Vegas, Nevada, USA"

Expert Tibia Nail

Expert Tibia Nail

The Expert Tibia Nailing System by Stahlmann Pro includes cannulated intramedullary nails, compatible locking screws, end caps, and dedicated instrumentation for selected adult tibial fracture fixation applications.

The catalogue lists nail diameters of 8–12 mm and lengths of 255–375 mm in 15 mm increments, with titanium alloy Ti-6Al-4V ELI and medical-grade stainless steel options. Multiple proximal locking positions and three distal locking holes provide configuration options for appropriately selected proximal, shaft, and distal tibial fractures.

Contact Stahlmann Pro to request the required sizes, compatible components, and an itemized quotation.

Product Specifications

Expert Tibia Nail

The Expert Tibia Nailing System is an intramedullary fixation system for selected adult fractures of the proximal tibia, tibial shaft, and distal tibia. It combines a cannulated nail with proximal and distal locking options, associated implant components, and dedicated surgical instruments.

The nail is positioned within the tibial medullary canal. Compatible locking components complete the selected construct and help maintain the planned relationship between fracture fragments.

For hospitals and distributors, a complete order should identify the nail dimensions, material, locking screws, end cap, and instrument requirements.

Explore the wider Stahlmann Pro Intramedullary Nailing System range for related products.

Expert-Tibia-Nailing-System

Design and Construction

Cannulated Nail

The catalogue describes a fully cannulated nail for insertion over a compatible guide wire. It lists reamed and selected unreamed applications, subject to the implant configuration and applicable technique.

Solid tibial nails for unreamed techniques are listed as available on special request. Their dimensions, ordering references, and instrument requirements should be confirmed separately.

Anatomical Profile

The nail incorporates an anatomical profile intended to accommodate tibial geometry. Diameter, length, canal shape, and entry approach remain important considerations during clinical planning.

The implant’s shape does not guarantee an exact fit in every patient. Selection and positioning must follow the product instructions and treating surgeon’s assessment.

Material Options

The catalogue lists:

  • Titanium alloy: Ti-6Al-4V ELI.
  • Medical-grade stainless steel.

Specify the requested material when preparing an enquiry. The exact stainless steel grade and supporting material documentation should be confirmed for the ordered configuration.

Proximal and Distal Locking

Proximal Locking

Multiple proximal locking positions provide configuration options for selected proximal tibial and shaft fracture applications.

The catalogue describes static and dynamic fixation options. Their selection depends on the fracture pattern and planned construct. The presence of multiple locking holes does not establish suitability for every proximal tibial fracture.

Tibial Shaft Fixation

For diaphyseal applications, proximal and distal locking form part of the fixation construct.

Static and dynamic configurations have different mechanical purposes. They should not be presented as interchangeable choices or as guarantees of fracture compression, alignment, or healing.

Distal Locking

The distal nail segment is described as having:

  • Two mediolateral locking holes.
  • One anteroposterior locking hole.

The specification illustration identifies 4.4 mm locking bolts for the distal holes. Confirm the compatible screw references and lengths for the selected nail before ordering.

Tibial-fixation-illustrations-showing-proximal,-shaft,-and-distal-configurations

Expert Tibia Nail Specifications

Specification Catalogue detail
System name Expert Tibia Nailing System
Implant type Tibial intramedullary nail
Patient group described Adults
Construction Cannulated
Nail diameters 8, 9, 10, 11, and 12 mm
Listed nail lengths 255, 270, 285, 300, 315, 330, 345, 360, and 375 mm
Length increments 15 mm
Material options Ti-6Al-4V ELI titanium alloy and medical-grade stainless steel
Proximal locking Multiple positions, including static and dynamic options
Distal locking Two mediolateral holes and one anteroposterior hole
Distal component diameter identified 4.4 mm
Special-request option Solid tibial nails for unreamed techniques

Nail Size Range

Shaft diameter Lengths listed in the specification section
8 mm 255–375 mm in 15 mm increments
9 mm 255–375 mm in 15 mm increments
10 mm 255–375 mm in 15 mm increments
11 mm 255–375 mm in 15 mm increments
12 mm 255–375 mm in 15 mm increments

These dimensions summarize the specification section. Request a confirmed product code for each configuration, particularly the 11 × 255 mm and 12 × 255 mm options.

Product-Specifications-Expert-Tibial-Nail

Applications Described in the Catalogue

The catalogue identifies the following adult applications:

Application Catalogue-listed description
Proximal tibial fractures Selected AO/OTA 41-A1, 41-A2, and 41-A3 patterns
Tibial shaft fractures AO/OTA 42-A, 42-B, and 42-C patterns
Distal tibial fractures Selected extra-articular AO/OTA 43-A1, 43-A2, and 43-A3 patterns with sufficient distal bone stock
Combined fracture patterns Selected fractures involving metaphyseal and diaphyseal regions
Delayed union and nonunion Selected cases requiring intramedullary stabilization
Impending pathological fractures Selected tibial lesions considered for prophylactic stabilization

These are catalogue descriptions. The product’s applicable instructions for use must establish the complete indications, contraindications, warnings, and precautions.

Fracture classification alone does not determine suitability. Clinical assessment must also consider anatomy, bone quality, soft-tissue condition, and other patient factors.

 

End-CapØ4.8-mm-Locking-Screw-Self-tappingØ4.4-mm-Locking-Screw-Self-tapping

End Caps

The end cap engages the proximal internal thread of the nail and covers its proximal opening. The catalogue describes this component as intended to limit bone and soft-tissue ingrowth into the opening.

Feature Catalogue detail
Component-page extensions 0, 5, 10, and 15 mm
Additional extension in ordering table 20 mm, subject to confirmation
Flush option 0 mm
Construction Cannulated
Material options Titanium alloy and medical-grade stainless steel

Select the extension according to nail position and the system instructions. The component should not be described as correcting improper nail placement.

Locking Screws

4.8 mm Self-Tapping Locking Screw

The catalogue describes a 4.8 mm self-tapping locking screw with a 3.5 mm hexagonal drive.

Feature Detail
Nominal diameter 4.8 mm
Thread design Self-tapping
Drive SW 3.5 mm hexagonal
Material options Titanium alloy and medical-grade stainless steel
Consistent entries in the ordering table 26–84 mm in 2 mm increments, plus 85 mm
Other entries Confirm the 25 mm option and 90 mm ordering reference

The screw length range should be confirmed against the corrected component list rather than inferred from the catalogue’s inconsistent increment statement.

4.4 mm Self-Tapping Locking Screw

The catalogue describes a 4.4 mm self-tapping locking screw, also with a 3.5 mm hexagonal drive.

The component description and ordering table give different length ranges. Request the verified size list and corresponding product codes before purchasing.

Feature Detail
Nominal diameter 4.4 mm
Thread design Self-tapping
Drive SW 3.5 mm hexagonal
Material options Titanium alloy and medical-grade stainless steel
Distal use Identified for the nail’s distal locking holes
Lengths and product codes Confirm against the corrected ordering list

Matching diameter alone does not establish compatibility with another nail system.

Expert Tibia Nailing Instrument Set

The catalogue includes a dedicated instrument set for guide-wire placement, canal preparation, nail insertion, locking, and extraction.

Selected Instrument Specifications

Instrument Catalogue detail
T-handle screwdriver SW 3.5 mm
T-handle universal screwdriver SW 6.5 mm
End-cap holder SW 3.5 mm
T-handle drill 5.2 mm diameter
Protection sleeve 12 mm diameter
Reamer head range 8.5–13 mm
Olive guide wire 2.5 mm × 1,000 mm
Cannulated chisel 12/3.2 mm designation
Temporary location rod 8.1/4.0 designation

Other listed items include a depth gauge, soft-tissue retractor, cannulated awl, proximal targeting device, targeting devices, flexible reamer bars, guide rods, drill bits, sleeves, connectors, wrenches, a hammer, and an aluminium box.

The instrument set is described as reusable. Cleaning, inspection, and sterilization must follow the applicable validated processing instructions. Confirm the final instrument names, specifications, and quantities in the quotation.

Clinical Planning and Follow-Up

The nail, locking components, and instruments should be evaluated as a compatible system.

Implant dimensions and locking configuration are selected by the treating surgical team. The product’s technique guide should govern instrument assembly and implantation.

Weight-bearing, rehabilitation, and follow-up depend on the fracture, fixation, patient assessment, and healing progress. The product name or locking design does not establish a universal recovery timetable.

Expert Tibia Nailing System Price and Ordering

To request an Expert Tibia Nailing System quotation, provide:

  • Required nail diameters and lengths.
  • Selected material.
  • Nail quantities.
  • Locking screw diameters, lengths, and quantities.
  • End-cap requirements.
  • Instrument set requirements.
  • Delivery destination.
  • Requested labeling and documentation.

Confirm whether the quotation covers implants only or includes the instruments.

For broader purchasing requirements, explore the Stahlmann Pro Trauma Implants range.

Request Product Information

Stahlmann Pro welcomes enquiries from hospitals and medical distributors in Africa, Latin America, and Russia.

Contact Stahlmann Pro for Expert Tibia Nailing System specifications, confirmed ordering references, and quotations.

Email: info@stahlmannpro.ae
Phone / WhatsApp: +971 50 975 0822

FAQs

What is the Expert Tibia Nailing System?

It is an intramedullary fixation system described in the catalogue for selected adult proximal, shaft, and distal tibial fracture applications.

Which nail diameters are listed?

The specification section lists 8, 9, 10, 11, and 12 mm diameters.

What nail lengths are listed?

Lengths range from 255 to 375 mm in 15 mm increments. Confirm the ordering reference for each required diameter-and-length combination.

Which materials are available?

The catalogue lists Ti-6Al-4V ELI titanium alloy and medical-grade stainless steel. Confirm material documentation for the selected product.

Is the nail cannulated?

Yes. The catalogue describes a cannulated nail and separately lists solid tibial nails for unreamed techniques on special request.

What distal locking arrangement is described?

Two mediolateral holes and one anteroposterior hole are described, with 4.4 mm locking bolts identified for the distal holes.

Are screws, end caps, and instruments included?

Confirm the itemized quotation. They should not be assumed to be included with the nail.

How can hospitals and distributors request pricing?

Send the required dimensions, materials, components, quantities, and destination through the Stahlmann Pro contact page.

Request a Quote

Related products

Request a Quote

WhatsApp Chat