Expert Femur Nail

Expert Femur Nail

Expert Femur Nail by Stahlmann Pro is a cannulated intramedullary fixation implant with a 5° proximal bend, left and right configurations, and standard or reconstruction locking options. Available shaft diameters range from 9–13 mm, with lengths from 320–440 mm. Compatible components include end caps, 4.9 mm self-tapping locking screws, and 6.4 mm cannulated anti-rotation screws. Minimum order quantity is one piece, with a stated delivery timeframe of 5–15 days, subject to confirmation.

Product Specifications

Expert Femur Nail

Expert Femur Nail by Stahlmann Pro is a cannulated intramedullary implant designed for femur fracture fixation. Its anatomical profile, 5° proximal bend, and multiple locking configurations provide options for appropriately selected femur shaft fractures and documented reconstruction applications.

Choosing a fixation system requires consideration of fracture location, bone anatomy, implant dimensions, and compatible components. The system offers separate left and right configurations, five shaft diameters, and seven nail lengths to support this selection process.

Stahlmann Pro welcomes enquiries from orthopedic surgeons, hospitals, procurement teams, and medical distributors in Africa, Latin America, and Russia.

Expert-Femur-Nail-implant

Expert Femur Nail Design and Features

Anatomical Profile

The nail incorporates a 5° proximal bend and an anatomical shape intended to accommodate femoral anatomy. Selecting the appropriate length, diameter, and side remains essential because canal geometry varies between patients.

Cannulated Construction

The cannulated design supports guide-wire-assisted insertion using compatible instrumentation. Guide-wire specifications and the intended insertion approach should be confirmed from the selected product’s instructions.

Proximal and Distal Locking

The catalogue describes three proximal locking holes with reconstruction locking capability. Distally, the nail features two static locking holes and one dynamic locking slot.

These options allow different fixation configurations. Their use depends on the fracture, selected components, and treatment plan.

Left and Right Configurations

Separate left and right models are listed. The side designation should be included in every order alongside the nail diameter, length, and product code.

Explore the Stahlmann Pro Intramedullary Nailing System for related products.

Expert Femur Nail Locking Options

Standard-Static-Locking         Dynamic-Locking         Full-length-nail-showing-the-5°-proximal-bend

 

Standard Static Locking

Static locking uses the designated screw positions to restrict axial movement and rotation between the nail and bone. It helps maintain the selected relationship between fracture fragments when a fixed construct is required.

Screw number and placement depend on fracture geometry, available bone fixation, and the system’s instructions. Static locking does not independently guarantee healing or a particular recovery time.

 

Dynamic Locking

Dynamic locking permits defined axial movement through a designated locking slot while retaining rotational control through the selected construct.

This option requires assessment of fracture stability, alignment, and the risk of shortening. It should not be selected solely because early weight-bearing is desired.

 

Compression and Dynamization

The catalogue identifies compression and dynamization features associated with dedicated locking slots.

Intraoperative compression brings suitable fracture surfaces closer together through the supported mechanism. Secondary dynamization is a later adjustment to the fixation construct when clinically indicated.

These are distinct interventions requiring compatible components and surgical assessment. Neither should be presented as a guaranteed solution for delayed healing or nonunion.

 

Indications and Reconstruction Configuration

Full-length-nail-showing-the-5°-proximal-bend

Standard Locking Indications

The supplied catalogue describes standard locking for femur shaft fractures requiring intramedullary stabilization. This may include simple or complex shaft patterns when appropriate alignment and fixation can be achieved.

The surgeon assesses fracture characteristics, bone quality, and available fixation before selecting the construct.

Proximal-nail-locking-hole-detail          6-4-mm-Cannulated-Anti-Rotation-ScrewReconstruction-Locking-Indications

Reconstruction Locking Indications

The catalogue describes reconstruction locking for selected femur shaft fractures associated with a femoral neck fracture on the same side.

This configuration accommodates screws directed toward the femoral neck and head while the nail supports shaft fixation. It requires the corresponding compatible reconstruction components.

Any additional application must follow the product’s documented indications. Reconstruction capability does not make the nail suitable for every isolated hip fracture.

Anti-Rotation Component

The 6.4 mm cannulated anti-rotation screw is described as assisting rotational control of the femoral neck fragment during reconstruction fixation. Required screw length and compatibility must be confirmed for the selected system.

Contraindications

The supplied catalogue lists:

  • Isolated femoral neck fractures.
  • Isolated intertrochanteric fractures.
  • Isolated subtrochanteric fractures.
  • Skeletally immature patients.
  • Active local or systemic infection.
  • Severe bone loss or inadequate bone quality preventing stable fixation.
  • Other patient-specific contraindications to intramedullary nailing.

 

A shaft fracture with an associated neck fracture is different from an isolated neck fracture. Consult the applicable instructions for the complete indications, contraindications, warnings, and precautions.

Expert Femur Nail Specifications

Full-length-nail-showing-the-5°-proximal-bend

Feature Catalogue specification
Brand Stahlmann Pro
Design Anatomical, cannulated
Proximal bend 5°
Shaft diameters 9, 10, 11, 12, and 13 mm
Nail lengths 320, 340, 360, 380, 400, 420, and 440 mm
Length increments 20 mm
Proximal diameter 13.5 mm
Configurations Left and right
Proximal locking Three locking holes with reconstruction capability
Distal locking Two static holes and one dynamic slot
Catalogue-listed materials Titanium alloy Ti-6Al-4V ELI and medical-grade stainless steel
Minimum order quantity 1 piece
OEM option Available, subject to agreed requirements
Packaging PE inner bag and carton
Stated delivery timeframe 5–15 days, subject to confirmation
Shipping options DHL, UPS, and FedEx, subject to destination availability

Confirm the material, supplied sterile or non-sterile condition, and processing requirements for the ordered product code.

 

Expert-Femur-Nail         Expert-Femur-Nail-End-Cap         Ø4.9-mm-Locking-Screw-Self-tapping         Ø6.4-mm-Cannulated-Anti-rotation-Screw-Self-tapping

Nail Sizes and Product Codes

The following titanium-coded entries are reproduced from the catalogue.

 

Diameter Length Left code Right code
9 mm 320 mm 6-210-09320Ti-L 6-210-09320Ti-R
9 mm 340 mm 6-210-09340Ti-L 6-210-09340Ti-R
9 mm 360 mm 6-210-09360Ti-L 6-210-09360Ti-R
9 mm 380 mm 6-210-09380Ti-L 6-210-09380Ti-R
9 mm 400 mm 6-210-09400Ti-L 6-210-09400Ti-R
9 mm 420 mm 6-210-09420Ti-L 6-210-09420Ti-R
9 mm 440 mm 6-210-09440Ti-L 6-210-09440Ti-R
10 mm 320 mm 6-210-10320Ti-L 6-210-10320Ti-R
10 mm 340 mm 6-210-10340Ti-L 6-210-10340Ti-R
10 mm 360 mm 6-210-10360Ti-L 6-210-10360Ti-R
10 mm 380 mm 6-210-10380Ti-L 6-210-10380Ti-R
10 mm 400 mm 6-210-10400Ti-L 6-210-10400Ti-R
10 mm 420 mm 6-210-10420Ti-L 6-210-10420Ti-R
10 mm 440 mm 6-210-10440Ti-L 6-210-10440Ti-R
11 mm 320 mm 6-210-11320Ti-L 6-210-11320Ti-R
11 mm 340 mm 6-210-11340Ti-L 6-210-11340Ti-R
11 mm 360 mm 6-210-11360Ti-L 6-210-11360Ti-R
11 mm 380 mm 6-210-11380Ti-L 6-210-11380Ti-R
11 mm 400 mm 6-210-11400Ti-L 6-210-11400Ti-R
11 mm 420 mm 6-210-11420Ti-L 6-210-11420Ti-R
11 mm 440 mm 6-210-11440Ti-L 6-210-11440Ti-R
12 mm 320 mm 6-210-12320Ti-L 6-210-12320Ti-R
12 mm 340 mm 6-210-12340Ti-L 6-210-12340Ti-R
12 mm 360 mm 6-210-12360Ti-L 6-210-12360Ti-R
12 mm 380 mm 6-210-12380Ti-L 6-210-12380Ti-R
12 mm 400 mm 6-210-12400Ti-L 6-210-12400Ti-R
12 mm 420 mm 6-210-12420Ti-L 6-210-12420Ti-R
12 mm 440 mm 6-210-12440Ti-L 6-210-12440Ti-R
13 mm 320 mm 6-210-13320Ti-L 6-210-13320Ti-R
13 mm 340 mm 6-210-13340Ti-L 6-210-13340Ti-R
13 mm 360 mm 6-210-13360Ti-L 6-210-13360Ti-R
13 mm 380 mm 6-210-13380Ti-L 6-210-13380Ti-R
13 mm 400 mm 6-210-13400Ti-L 6-210-13400Ti-R
13 mm 420 mm 6-210-13420Ti-L 6-210-13420Ti-R
13 mm 440 mm 6-210-13440Ti-L 6-210-13440Ti-R

Compatible Components

End Cap

The end cap engages the proximal internal thread and is designed to limit tissue ingrowth into the nail’s proximal opening. The catalogue describes a flush 0 mm option and extended options for adjusting proximal extension.

Its cannulated design supports guide-wire-assisted placement with compatible instruments.

Product code Listed length
6-212-00Ti 0 mm
6-212-05Ti 5 mm
6-212-10Ti 10 mm
6-212-15Ti 15 mm
6-212-20Ti 20 mm

Ø4.9 mm Self-Tapping Locking Screw

The 4.9 mm locking screw features a self-tapping thread and 3.5 mm hexagonal drive. Required lengths and quantities depend on the planned fixation configuration.

Feature Specification
Diameter 4.9 mm
Thread Self-tapping
Drive 3.5 mm hexagonal
Listed length range 26–90 mm
Catalogue-listed materials Ti-6Al-4V ELI titanium alloy and medical-grade stainless steel
Product code Length
6-214-26Ti 26 mm
6-214-28Ti 28 mm
6-214-30Ti 30 mm
6-214-32Ti 32 mm
6-214-34Ti 34 mm
6-214-36Ti 36 mm
6-214-38Ti 38 mm
6-214-40Ti 40 mm
6-214-42Ti 42 mm
6-214-44Ti 44 mm
6-214-46Ti 46 mm
6-214-48Ti 48 mm
6-214-50Ti 50 mm
6-214-52Ti 52 mm
6-214-54Ti 54 mm
6-214-56Ti 56 mm
6-214-58Ti 58 mm
6-214-60Ti 60 mm
6-214-62Ti 62 mm
6-214-64Ti 64 mm
6-214-66Ti 66 mm
6-214-68Ti 68 mm
6-214-70Ti 70 mm
6-214-72Ti 72 mm
6-214-74Ti 74 mm
6-214-76Ti 76 mm
6-214-78Ti 78 mm
6-214-80Ti 80 mm
6-214-82Ti 82 mm
6-214-84Ti 84 mm
6-214-85Ti 85 mm
6-214-90Ti 90 mm

Ø6.4 mm Cannulated Anti-Rotation Screw

This reconstruction component is described as assisting rotational control of the femoral neck fragment. It has a self-tapping thread, cannulated construction, and 3.5 mm hexagonal drive.

The illustration identifies a 2.5 mm wire passage. Confirm the specified guide wire and instrument compatibility before use.

Feature Specification
Diameter 6.4 mm
Construction Cannulated
Thread Self-tapping
Drive 3.5 mm hexagonal
Listed wire passage 2.5 mm
Length range 60–130 mm
Length increments 5 mm
Catalogue-listed materials Ti-6Al-4V ELI titanium alloy and medical-grade stainless steel
Product code Length
6-216-60Ti 60 mm
6-216-65Ti 65 mm
6-216-70Ti 70 mm
6-216-75Ti 75 mm
6-216-80Ti 80 mm
6-216-85Ti 85 mm
6-216-90Ti 90 mm
6-216-95Ti 95 mm
6-216-100Ti 100 mm
6-216-105Ti 105 mm
6-216-110Ti 110 mm
6-216-115Ti 115 mm
6-216-120Ti 120 mm
6-216-125Ti 125 mm
6-216-130Ti 130 mm

Clinical Planning and Follow-Up

The intended insertion route, canal preparation, and locking configuration must follow the selected implant’s instructions. Antegrade and retrograde insertion should not be assumed to be interchangeable for every nail.

Postoperative weight-bearing and rehabilitation depend on the injury, fixation stability, and healing progress. The treating surgeon determines the appropriate activity level and follow-up schedule.

For general professional background, consult the AO Surgery Reference guidance on femur shaft intramedullary nailing. This educational resource does not replace product instructions or represent an endorsement of Stahlmann Pro.

Request Expert Femur Nail Pricing

Stahlmann Pro welcomes purchasing enquiries from Africa, Latin America, and Russia. Provide the required product codes, side, dimensions, quantities, and component requirements for an accurate quotation.

For hospital tenders, include the requested material documentation, labeling, traceability, and destination-specific requirements.

View the wider Trauma Implants range or contact the team directly.

Email: info@stahlmannpro.ae
Phone / WhatsApp: +971 50 975 0822
Enquiries: Contact Stahlmann Pro

FAQs

What sizes are available for the Expert Femur Nail?

The catalogue lists shaft diameters of 9, 10, 11, 12, and 13 mm. Lengths range from 320–440 mm in 20 mm increments, with separate left and right product codes.

What is the difference between standard and reconstruction locking?

Standard locking provides proximal and distal fixation for the shaft construct. Reconstruction locking includes a screw arrangement directed toward the femoral neck and head for the documented combined fracture application.

Can this nail treat an isolated femoral neck fracture?

The supplied catalogue lists isolated femoral neck fractures as a contraindication. Reconstruction locking is described for selected shaft fractures with an associated neck fracture.

Are screws, end caps, and instruments included?

Order contents must be confirmed in the quotation. The nail and its compatible components should not be assumed to be supplied as one complete set.

What is the minimum order quantity?

The stated minimum order quantity is one piece. Delivery is quoted as 5–15 days, subject to configuration, availability, and destination confirmation.

Request a Quote