WHX Miami 2026 "June 17–19, 2026 Miami Beach Convention Center, USA"
EUROSPINE 2026 "October 7–9, 2026 Gothia Towers & Svenska Mässan, Gothenburg, Sweden"
MEDICA 2026 "November 16–19, 2026 Messe Düsseldorf, Germany"
WHX Dubai 2027 "January 25–28, 2027 Dubai Exhibition Centre, UAE"
AAOS 2027 "March 3–6, 2027 Venetian Convention & Expo Center, Las Vegas, Nevada, USA"
WHX Miami 2026 "June 17–19, 2026 Miami Beach Convention Center, USA"
EUROSPINE 2026 "October 7–9, 2026 Gothia Towers & Svenska Mässan, Gothenburg, Sweden"
MEDICA 2026 "November 16–19, 2026 Messe Düsseldorf, Germany"
WHX Dubai 2027 "January 25–28, 2027 Dubai Exhibition Centre, UAE"
AAOS 2027 "March 3–6, 2027 Venetian Convention & Expo Center, Las Vegas, Nevada, USA"
The Tibia Intramedullary Nail, presented in the catalogue as the Expert Tibia Nailing System, is designed for selected adult tibial fracture fixation applications. Its cannulated construction supports guide-wire-assisted insertion, while multiple proximal and distal locking positions provide options for the planned fixation construct.
The catalogue lists 8–12 mm diameters and 255–375 mm lengths, with titanium alloy Ti-6Al-4V ELI and medical-grade stainless steel options. Request the required nail configuration, compatible locking screws, end caps, and instruments through the contact page.
The Tibia Intramedullary Nail is an internal fixation implant for selected adult fractures of the tibia. The nail is positioned within the medullary canal and secured using compatible locking components.
Presented in the catalogue as the Expert Tibia Nailing System, the range combines cannulated nails, locking screws, end caps, and dedicated instrumentation. Product selection requires consideration of nail dimensions, material, fracture location, and the complete fixation arrangement.
Explore the Intramedullary Nailing System category for related products.
The nail has a cannulated design for insertion over a compatible guide wire. The catalogue describes reamed and selected unreamed applications, according to the implant configuration and applicable technique.
Solid tibial nails for unreamed techniques are listed as available on special request. Confirm their specifications and matching instrumentation separately.
The shaped nail profile is intended to accommodate tibial anatomy. Correct diameter, length, and positioning remain important because anatomy and fracture characteristics differ between patients.
The implant’s geometry should not be described as guaranteeing protection of the knee, patellar tendon, or surrounding tissues.
Multiple proximal locking positions provide configuration options for selected proximal and shaft fracture applications.
The catalogue describes static and dynamic fixation capabilities. The appropriate arrangement depends on the fracture and the planned construct.
The distal segment incorporates:
The catalogue identifies 4.4 mm locking bolts for the distal holes. Confirm the corresponding screw references and lengths for the selected nail.
The catalogue lists Ti-6Al-4V ELI titanium alloy and medical-grade stainless steel.
Specify the requested material when preparing an enquiry. Supporting material documentation should apply to the actual implant and components being ordered.
| Specification | Detail |
|---|---|
| Product name | Tibia Intramedullary Nail |
| Catalogue system | Expert Tibia Nailing System |
| Patient group described | Adults |
| Construction | Cannulated |
| Nail diameters | 8, 9, 10, 11, and 12 mm |
| Listed nail lengths | 255, 270, 285, 300, 315, 330, 345, 360, and 375 mm |
| Length increments | 15 mm |
| Material options | Ti-6Al-4V ELI titanium alloy and medical-grade stainless steel |
| Proximal locking | Multiple positions, including static and dynamic options |
| Distal locking | Two mediolateral holes and one anteroposterior hole |
| Distal locking component | 4.4 mm, as identified in the catalogue |
| Special-request option | Solid tibial nails for unreamed techniques |
The size range summarizes the specification section. Confirm the exact ordering code and availability of each diameter-and-length combination.
The catalogue identifies selected adult applications involving:
These descriptions must be considered alongside the applicable instructions for use. Fracture classification alone does not determine whether a particular nail configuration is suitable.
The treating surgical team assesses the injury, anatomy, bone quality, soft tissues, and other patient factors before selecting fixation.
The catalogue describes 4.8 mm and 4.4 mm self-tapping locking screws, both with SW 3.5 mm hexagonal drives.
Select screw lengths and quantities according to the planned construct and confirmed compatibility. Request the corrected component ordering list where catalogue entries are inconsistent.
End caps engage the nail’s proximal internal thread and cover its proximal opening. The component description lists 0, 5, 10, and 15 mm options.
The 0 mm end cap is described as flush. Extended options should be selected according to nail position and system instructions.
A 20 mm option also appears in the ordering table. Confirm its availability and reference before ordering.
The Expert Tibia Nailing Instrument Set includes instruments for guide-wire placement, canal preparation, insertion, locking, and extraction.
Selected catalogue items include:
| Instrument | Listed specification |
|---|---|
| T-handle screwdriver | SW 3.5 mm |
| T-handle universal screwdriver | SW 6.5 mm |
| End-cap holder | SW 3.5 mm |
| T-handle drill | 5.2 mm diameter |
| Protection sleeve | 12 mm diameter |
| Reamer heads | 8.5–13 mm range |
| Olive guide wire | 2.5 mm × 1,000 mm |
Other listed instruments include targeting devices, drill bits, a depth gauge, flexible reamer bars, sleeves, connectors, a cannulated awl, and extraction-related instruments.
Confirm the instrument list and quantities in the quotation. Reusable instruments must be processed according to their validated cleaning and sterilization instructions.
Nail selection, surgical approach, canal preparation, and locking configuration must follow the selected system’s instructions and clinical assessment.
The implant does not establish a universal weight-bearing or recovery schedule. Rehabilitation and follow-up are determined by the treating team according to fixation stability, patient needs, and healing progress.
For an accurate tibial nail quotation, provide:
Ask for an itemized quotation to establish whether the nail, screws, end cap, and instruments are included or listed separately.
For broader purchasing requirements, explore the Trauma Implants range.
Hospitals and distributors in Africa, Latin America, and Russia can contact our team for specifications, confirmed product references, and quotations.
Email: info@stahlmannpro.ae
Phone / WhatsApp: +971 50 975 0822
It is an implant positioned within the tibial medullary canal and used with compatible locking components for selected fracture fixation applications.
The catalogue lists 8, 9, 10, 11, and 12 mm diameters.
The specification section lists 255–375 mm lengths in 15 mm increments. Confirm the product code for the required combination.
Yes. The catalogue describes cannulated nails and separately lists solid options on special request.
Both material options appear in the catalogue. Confirm availability and material documentation for the selected configuration.
Confirm the quotation contents. Components and instruments should not be assumed to be included with the nail.
Removal is an individual clinical decision. The product description should not promise a fixed removal date or describe removal as universally straightforward.