Expert Femur Nail by Stahlmann Pro is a cannulated intramedullary fixation implant with a 5° proximal bend, left and right configurations, and standard or reconstruction locking options. Available shaft diameters range from 9–13 mm, with lengths from 320–440 mm. Compatible components include end caps, 4.9 mm self-tapping locking screws, and 6.4 mm cannulated anti-rotation screws. Minimum order quantity is one piece, with a stated delivery timeframe of 5–15 days, subject to confirmation.
Expert Femur Nail by Stahlmann Pro is a cannulated intramedullary implant designed for femur fracture fixation. Its anatomical profile, 5° proximal bend, and multiple locking configurations provide options for appropriately selected femur shaft fractures and documented reconstruction applications.
Choosing a fixation system requires consideration of fracture location, bone anatomy, implant dimensions, and compatible components. The system offers separate left and right configurations, five shaft diameters, and seven nail lengths to support this selection process.
Stahlmann Pro welcomes enquiries from orthopedic surgeons, hospitals, procurement teams, and medical distributors in Africa, Latin America, and Russia.
The nail incorporates a 5° proximal bend and an anatomical shape intended to accommodate femoral anatomy. Selecting the appropriate length, diameter, and side remains essential because canal geometry varies between patients.
The cannulated design supports guide-wire-assisted insertion using compatible instrumentation. Guide-wire specifications and the intended insertion approach should be confirmed from the selected product’s instructions.
The catalogue describes three proximal locking holes with reconstruction locking capability. Distally, the nail features two static locking holes and one dynamic locking slot.
These options allow different fixation configurations. Their use depends on the fracture, selected components, and treatment plan.
Separate left and right models are listed. The side designation should be included in every order alongside the nail diameter, length, and product code.
Explore the Stahlmann Pro Intramedullary Nailing System for related products.


Static locking uses the designated screw positions to restrict axial movement and rotation between the nail and bone. It helps maintain the selected relationship between fracture fragments when a fixed construct is required.
Screw number and placement depend on fracture geometry, available bone fixation, and the system’s instructions. Static locking does not independently guarantee healing or a particular recovery time.
Dynamic locking permits defined axial movement through a designated locking slot while retaining rotational control through the selected construct.
This option requires assessment of fracture stability, alignment, and the risk of shortening. It should not be selected solely because early weight-bearing is desired.
The catalogue identifies compression and dynamization features associated with dedicated locking slots.
Intraoperative compression brings suitable fracture surfaces closer together through the supported mechanism. Secondary dynamization is a later adjustment to the fixation construct when clinically indicated.
These are distinct interventions requiring compatible components and surgical assessment. Neither should be presented as a guaranteed solution for delayed healing or nonunion.
The supplied catalogue describes standard locking for femur shaft fractures requiring intramedullary stabilization. This may include simple or complex shaft patterns when appropriate alignment and fixation can be achieved.
The surgeon assesses fracture characteristics, bone quality, and available fixation before selecting the construct.

The catalogue describes reconstruction locking for selected femur shaft fractures associated with a femoral neck fracture on the same side.
This configuration accommodates screws directed toward the femoral neck and head while the nail supports shaft fixation. It requires the corresponding compatible reconstruction components.
Any additional application must follow the product’s documented indications. Reconstruction capability does not make the nail suitable for every isolated hip fracture.
The 6.4 mm cannulated anti-rotation screw is described as assisting rotational control of the femoral neck fragment during reconstruction fixation. Required screw length and compatibility must be confirmed for the selected system.
The supplied catalogue lists:
A shaft fracture with an associated neck fracture is different from an isolated neck fracture. Consult the applicable instructions for the complete indications, contraindications, warnings, and precautions.
| Feature | Catalogue specification |
|---|---|
| Brand | Stahlmann Pro |
| Design | Anatomical, cannulated |
| Proximal bend | 5° |
| Shaft diameters | 9, 10, 11, 12, and 13 mm |
| Nail lengths | 320, 340, 360, 380, 400, 420, and 440 mm |
| Length increments | 20 mm |
| Proximal diameter | 13.5 mm |
| Configurations | Left and right |
| Proximal locking | Three locking holes with reconstruction capability |
| Distal locking | Two static holes and one dynamic slot |
| Catalogue-listed materials | Titanium alloy Ti-6Al-4V ELI and medical-grade stainless steel |
| Minimum order quantity | 1 piece |
| OEM option | Available, subject to agreed requirements |
| Packaging | PE inner bag and carton |
| Stated delivery timeframe | 5–15 days, subject to confirmation |
| Shipping options | DHL, UPS, and FedEx, subject to destination availability |
Confirm the material, supplied sterile or non-sterile condition, and processing requirements for the ordered product code.



The following titanium-coded entries are reproduced from the catalogue.
| Diameter | Length | Left code | Right code |
|---|---|---|---|
| 9 mm | 320 mm | 6-210-09320Ti-L | 6-210-09320Ti-R |
| 9 mm | 340 mm | 6-210-09340Ti-L | 6-210-09340Ti-R |
| 9 mm | 360 mm | 6-210-09360Ti-L | 6-210-09360Ti-R |
| 9 mm | 380 mm | 6-210-09380Ti-L | 6-210-09380Ti-R |
| 9 mm | 400 mm | 6-210-09400Ti-L | 6-210-09400Ti-R |
| 9 mm | 420 mm | 6-210-09420Ti-L | 6-210-09420Ti-R |
| 9 mm | 440 mm | 6-210-09440Ti-L | 6-210-09440Ti-R |
| 10 mm | 320 mm | 6-210-10320Ti-L | 6-210-10320Ti-R |
| 10 mm | 340 mm | 6-210-10340Ti-L | 6-210-10340Ti-R |
| 10 mm | 360 mm | 6-210-10360Ti-L | 6-210-10360Ti-R |
| 10 mm | 380 mm | 6-210-10380Ti-L | 6-210-10380Ti-R |
| 10 mm | 400 mm | 6-210-10400Ti-L | 6-210-10400Ti-R |
| 10 mm | 420 mm | 6-210-10420Ti-L | 6-210-10420Ti-R |
| 10 mm | 440 mm | 6-210-10440Ti-L | 6-210-10440Ti-R |
| 11 mm | 320 mm | 6-210-11320Ti-L | 6-210-11320Ti-R |
| 11 mm | 340 mm | 6-210-11340Ti-L | 6-210-11340Ti-R |
| 11 mm | 360 mm | 6-210-11360Ti-L | 6-210-11360Ti-R |
| 11 mm | 380 mm | 6-210-11380Ti-L | 6-210-11380Ti-R |
| 11 mm | 400 mm | 6-210-11400Ti-L | 6-210-11400Ti-R |
| 11 mm | 420 mm | 6-210-11420Ti-L | 6-210-11420Ti-R |
| 11 mm | 440 mm | 6-210-11440Ti-L | 6-210-11440Ti-R |
| 12 mm | 320 mm | 6-210-12320Ti-L | 6-210-12320Ti-R |
| 12 mm | 340 mm | 6-210-12340Ti-L | 6-210-12340Ti-R |
| 12 mm | 360 mm | 6-210-12360Ti-L | 6-210-12360Ti-R |
| 12 mm | 380 mm | 6-210-12380Ti-L | 6-210-12380Ti-R |
| 12 mm | 400 mm | 6-210-12400Ti-L | 6-210-12400Ti-R |
| 12 mm | 420 mm | 6-210-12420Ti-L | 6-210-12420Ti-R |
| 12 mm | 440 mm | 6-210-12440Ti-L | 6-210-12440Ti-R |
| 13 mm | 320 mm | 6-210-13320Ti-L | 6-210-13320Ti-R |
| 13 mm | 340 mm | 6-210-13340Ti-L | 6-210-13340Ti-R |
| 13 mm | 360 mm | 6-210-13360Ti-L | 6-210-13360Ti-R |
| 13 mm | 380 mm | 6-210-13380Ti-L | 6-210-13380Ti-R |
| 13 mm | 400 mm | 6-210-13400Ti-L | 6-210-13400Ti-R |
| 13 mm | 420 mm | 6-210-13420Ti-L | 6-210-13420Ti-R |
| 13 mm | 440 mm | 6-210-13440Ti-L | 6-210-13440Ti-R |
The end cap engages the proximal internal thread and is designed to limit tissue ingrowth into the nail’s proximal opening. The catalogue describes a flush 0 mm option and extended options for adjusting proximal extension.
Its cannulated design supports guide-wire-assisted placement with compatible instruments.
| Product code | Listed length |
|---|---|
| 6-212-00Ti | 0 mm |
| 6-212-05Ti | 5 mm |
| 6-212-10Ti | 10 mm |
| 6-212-15Ti | 15 mm |
| 6-212-20Ti | 20 mm |
The 4.9 mm locking screw features a self-tapping thread and 3.5 mm hexagonal drive. Required lengths and quantities depend on the planned fixation configuration.
| Feature | Specification |
|---|---|
| Diameter | 4.9 mm |
| Thread | Self-tapping |
| Drive | 3.5 mm hexagonal |
| Listed length range | 26–90 mm |
| Catalogue-listed materials | Ti-6Al-4V ELI titanium alloy and medical-grade stainless steel |
| Product code | Length |
|---|---|
| 6-214-26Ti | 26 mm |
| 6-214-28Ti | 28 mm |
| 6-214-30Ti | 30 mm |
| 6-214-32Ti | 32 mm |
| 6-214-34Ti | 34 mm |
| 6-214-36Ti | 36 mm |
| 6-214-38Ti | 38 mm |
| 6-214-40Ti | 40 mm |
| 6-214-42Ti | 42 mm |
| 6-214-44Ti | 44 mm |
| 6-214-46Ti | 46 mm |
| 6-214-48Ti | 48 mm |
| 6-214-50Ti | 50 mm |
| 6-214-52Ti | 52 mm |
| 6-214-54Ti | 54 mm |
| 6-214-56Ti | 56 mm |
| 6-214-58Ti | 58 mm |
| 6-214-60Ti | 60 mm |
| 6-214-62Ti | 62 mm |
| 6-214-64Ti | 64 mm |
| 6-214-66Ti | 66 mm |
| 6-214-68Ti | 68 mm |
| 6-214-70Ti | 70 mm |
| 6-214-72Ti | 72 mm |
| 6-214-74Ti | 74 mm |
| 6-214-76Ti | 76 mm |
| 6-214-78Ti | 78 mm |
| 6-214-80Ti | 80 mm |
| 6-214-82Ti | 82 mm |
| 6-214-84Ti | 84 mm |
| 6-214-85Ti | 85 mm |
| 6-214-90Ti | 90 mm |
This reconstruction component is described as assisting rotational control of the femoral neck fragment. It has a self-tapping thread, cannulated construction, and 3.5 mm hexagonal drive.
The illustration identifies a 2.5 mm wire passage. Confirm the specified guide wire and instrument compatibility before use.
| Feature | Specification |
|---|---|
| Diameter | 6.4 mm |
| Construction | Cannulated |
| Thread | Self-tapping |
| Drive | 3.5 mm hexagonal |
| Listed wire passage | 2.5 mm |
| Length range | 60–130 mm |
| Length increments | 5 mm |
| Catalogue-listed materials | Ti-6Al-4V ELI titanium alloy and medical-grade stainless steel |
| Product code | Length |
|---|---|
| 6-216-60Ti | 60 mm |
| 6-216-65Ti | 65 mm |
| 6-216-70Ti | 70 mm |
| 6-216-75Ti | 75 mm |
| 6-216-80Ti | 80 mm |
| 6-216-85Ti | 85 mm |
| 6-216-90Ti | 90 mm |
| 6-216-95Ti | 95 mm |
| 6-216-100Ti | 100 mm |
| 6-216-105Ti | 105 mm |
| 6-216-110Ti | 110 mm |
| 6-216-115Ti | 115 mm |
| 6-216-120Ti | 120 mm |
| 6-216-125Ti | 125 mm |
| 6-216-130Ti | 130 mm |
The intended insertion route, canal preparation, and locking configuration must follow the selected implant’s instructions. Antegrade and retrograde insertion should not be assumed to be interchangeable for every nail.
Postoperative weight-bearing and rehabilitation depend on the injury, fixation stability, and healing progress. The treating surgeon determines the appropriate activity level and follow-up schedule.
For general professional background, consult the AO Surgery Reference guidance on femur shaft intramedullary nailing. This educational resource does not replace product instructions or represent an endorsement of Stahlmann Pro.
Stahlmann Pro welcomes purchasing enquiries from Africa, Latin America, and Russia. Provide the required product codes, side, dimensions, quantities, and component requirements for an accurate quotation.
For hospital tenders, include the requested material documentation, labeling, traceability, and destination-specific requirements.
View the wider Trauma Implants range or contact the team directly.
Email: info@stahlmannpro.ae
Phone / WhatsApp: +971 50 975 0822
Enquiries: Contact Stahlmann Pro
The catalogue lists shaft diameters of 9, 10, 11, 12, and 13 mm. Lengths range from 320–440 mm in 20 mm increments, with separate left and right product codes.
Standard locking provides proximal and distal fixation for the shaft construct. Reconstruction locking includes a screw arrangement directed toward the femoral neck and head for the documented combined fracture application.
The supplied catalogue lists isolated femoral neck fractures as a contraindication. Reconstruction locking is described for selected shaft fractures with an associated neck fracture.
Order contents must be confirmed in the quotation. The nail and its compatible components should not be assumed to be supplied as one complete set.
The stated minimum order quantity is one piece. Delivery is quoted as 5–15 days, subject to configuration, availability, and destination confirmation.