Specifications
Indications for use
It is used in the fixation of Large Fragment Locking Plates.
Specifications
Indications for use
It is used in the fixation of Large Fragment Locking Plates.
| Length (mm) | Stainless Steel | Titanium |
| 20 | 3-280-20 | 3-280-20Ti |
| 25 | 3-280-25 | 3-280-25Ti |
| 30 | 3-280-30 | 3-280-30Ti |
| 35 | 3-280-35 | 3-280-35Ti |
| 40 | 3-280-40 | 3-280-40Ti |
| 45 | 3-280-45 | 3-280-45Ti |
| 50 | 3-280-50 | 3-280-50Ti |
| 55 | 3-280-55 | 3-280-55Ti |
| 60 | 3-280-60 | 3-280-60Ti |
| 65 | 3-280-65 | 3-280-65Ti |
| 70 | 3-280-70 | 3-280-70Ti |
| 75 | 3-280-75 | 3-280-75Ti |
| 80 | 3-280-80 | 3-280-80Ti |
| 85 | 3-280-85 | 3-280-85Ti |
| 90 | 3-280-90 | 3-280-90Ti |
| 95 | 3-280-95 | 3-280-95Ti |
| 100 | 3-280-100 | 3-280-100Ti |
| 105 | 3-280-105 | 3-280-105Ti |
| 110 | 3-280-110 | 3-280-110Ti |
| 115 | 3-280-115 | 3-280-115Ti |
| 120 | 3-280-120 | 3-280-120Ti |
7.3mm Cannulated Conical Screws are designed for fixation of large fragment locking plates. They can help provide fixation and interfragmentary compression when used as indicated by a qualified orthopedic surgeon.
These screws feature a 7.3mm diameter, fully threaded shaft, non threaded conical head, and self tapping tip. The self tapping design can help ease insertion during the appropriate surgical procedure.
The screws are available in lengths ranging from 20 mm to 120 mm, allowing selection according to the surgical application and required fixation depth.
Yes. StahlmannPro lists these screws in both titanium and stainless steel options. The appropriate material should be selected according to the implant system and clinical requirements.
The self tapping tip allows the screw to create its own thread path during insertion, which can simplify the insertion process when the screw is used according to the applicable surgical technique and instrumentation.