4.5 / 5.0mm Proximal Femoral Lateral Locking Plate (Type-II)

4.5 / 5.0mm Proximal Femoral Lateral Locking Plate (Type-II)

Specifications

  • Plates(Right & Left) available in both-Titanium & Stainless steel.
  • Plate features locking compression holes and round locking holes that accepts 4.5/5.0mm cortical and locking screws.
  • Plate available with 4,5,6,7,8,9,10,12,14 & 16 holes

Indications for use

4.5/5.0mm Wise Lock Proximal Femoral Lateral Plate is intended for:

  • Fractures of the femur including: fractures of the trochanteric region, trochanteric simple, cervicotrochanteric region, trochanterodiaphyseal, multifragmentary pertrochanteric, intertrochanteric, intertrochanteric reversed, or transverse or with additional fracture of medial cortex.

Fractures of the proximal end of the femur combined with ispsilateral shaft fractures, metastatic fracture of the proximal femur and osteotomies of the proximal femur.

Product Specifications

Specifications

  • Plates(Right & Left) available in both-Titanium & Stainless steel.
  • Plate features locking compression holes and round locking holes that accepts 4.5/5.0mm cortical and locking screws.
  • Plate available with 4,5,6,7,8,9,10,12,14 & 16 holes

Indications for use

4.5/5.0mm Wise Lock Proximal Femoral Lateral Plate is intended for:

  • Fractures of the femur including: fractures of the trochanteric region, trochanteric simple, cervicotrochanteric region, trochanterodiaphyseal, multifragmentary pertrochanteric, intertrochanteric, intertrochanteric reversed, or transverse or with additional fracture of medial cortex.

Fractures of the proximal end of the femur combined with ispsilateral shaft fractures, metastatic fracture of the proximal femur and osteotomies of the proximal femur.

Holes Stainless Steel

Right

Titanium

Right

Stainless Steel

Left

Titanium

Left

4 3-120-04R 3-120-04R-Ti 3-120-04L 3-120-04L-Ti
5 3-120-05R 3-120-05R-Ti 3-120-05L 3-120-05L-Ti
6 3-120-06R 3-120-06R-Ti 3-120-06L 3-120-06L-Ti
7 3-120-07R 3-120-07R-Ti 3-120-07L 3-120-07L-Ti
8 3-120-08R 3-120-08R-Ti 3-120-08L 3-120-08L-Ti
9 3-120-09R 3-120-09R-Ti 3-120-09L 3-120-09L-Ti
10 3-120-10R 3-120-10R-Ti 3-120-10L 3-120-10L-Ti
12 3-120-12R 3-120-12R-Ti 3-120-12L 3-120-12L-Ti
14 3-120-14R 3-120-14R-Ti 3-120-14L 3-120-14L-Ti
16 3-120-16R 3-120-16R-Ti 3-120-16L 3-120-16L-Ti