95° DCS Locking Plate

95° DCS Locking Plate

Specification

  • Available in both Titanium & Stainless steel.
  • Plate features locking compression holes and round locking holes that accepts 4.5/5.0mm cortical and locking screws.
  • Plate available with 6,7,8,9,10,12,14,16,18,20,22 holes.

Indications for use

95° DCS Locking Plate is intended for use in fixation of fractures to the proximal femur. The system is indicated for use in trochanteric, pertrochanteric, intertrochanteric, and basilar neck fracture.

Product Specifications

Specification

  • Available in both Titanium & Stainless steel.
  • Plate features locking compression holes and round locking holes that accepts 4.5/5.0mm cortical and locking screws.
  • Plate available with 6,7,8,9,10,12,14,16,18,20,22 holes.

Indications for use

95° DCS Locking Plate is intended for use in fixation of fractures to the proximal femur. The system is indicated for use in trochanteric, pertrochanteric, intertrochanteric, and basilar neck fracture.

Holes Stainless Steel Titanium
6 3-154-06 3-154-06Ti
7 3-154-07 3-154-07Ti
8 3-154-08 3-154-08Ti
9 3-154-09 3-154-09Ti
10 3-154-10 3-154-10Ti
12 3-154-12 3-154-12Ti
14 3-154-14 3-154-14Ti
16 3-154-16 3-154-16Ti
18 3-154-18 3-154-18Ti
20 3-154-20 3-154-20Ti
22 3-154-22 3-154-22Ti

 

FAQs

What is a 95° DCS Locking Plate?

The 95° DCS Locking Plate is an orthopedic fixation plate designed for fracture fixation of the proximal femur. It is intended for use in specific proximal femoral fractures, including trochanteric, pertrochanteric, intertrochanteric, and basilar neck fractures.

What materials are available for the 95° DCS Locking Plate?

The 95° DCS Locking Plate is available in both titanium and stainless steel options, allowing healthcare professionals to select the appropriate material according to surgical requirements.

Which screws are compatible with the 95° DCS Locking Plate?

The plate features locking compression holes and round locking holes designed to accept 4.5 mm and 5.0 mm cortical and locking screws.

What plate sizes are available?

The 95° DCS Locking Plate is available in multiple configurations with 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, or 22 holes. The appropriate configuration depends on the fracture pattern and surgical plan.

What fractures can be treated with a 95° DCS Locking Plate?

The system is intended for fixation of proximal femur fractures, including trochanteric, pertrochanteric, intertrochanteric, and basilar neck fractures. Selection and use should be determined by a qualified orthopedic surgeon based on the patient's fracture characteristics.