Specification
Indications for use
95° DCS Locking Plate is intended for use in fixation of fractures to the proximal femur. The system is indicated for use in trochanteric, pertrochanteric, intertrochanteric, and basilar neck fracture.
Specification
Indications for use
95° DCS Locking Plate is intended for use in fixation of fractures to the proximal femur. The system is indicated for use in trochanteric, pertrochanteric, intertrochanteric, and basilar neck fracture.
| Holes | Stainless Steel | Titanium |
| 6 | 3-154-06 | 3-154-06Ti |
| 7 | 3-154-07 | 3-154-07Ti |
| 8 | 3-154-08 | 3-154-08Ti |
| 9 | 3-154-09 | 3-154-09Ti |
| 10 | 3-154-10 | 3-154-10Ti |
| 12 | 3-154-12 | 3-154-12Ti |
| 14 | 3-154-14 | 3-154-14Ti |
| 16 | 3-154-16 | 3-154-16Ti |
| 18 | 3-154-18 | 3-154-18Ti |
| 20 | 3-154-20 | 3-154-20Ti |
| 22 | 3-154-22 | 3-154-22Ti |
The 95° DCS Locking Plate is an orthopedic fixation plate designed for fracture fixation of the proximal femur. It is intended for use in specific proximal femoral fractures, including trochanteric, pertrochanteric, intertrochanteric, and basilar neck fractures.
The 95° DCS Locking Plate is available in both titanium and stainless steel options, allowing healthcare professionals to select the appropriate material according to surgical requirements.
The plate features locking compression holes and round locking holes designed to accept 4.5 mm and 5.0 mm cortical and locking screws.
The 95° DCS Locking Plate is available in multiple configurations with 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, or 22 holes. The appropriate configuration depends on the fracture pattern and surgical plan.
The system is intended for fixation of proximal femur fractures, including trochanteric, pertrochanteric, intertrochanteric, and basilar neck fractures. Selection and use should be determined by a qualified orthopedic surgeon based on the patient's fracture characteristics.