Specifications
Indications for use
DHS Locking Plate is intended for use in fixation of fractures to the proximal femur. The system is indicated for use in trochanteric, pertrochanteric, intertrochanteric, and basilar neck fracture.
Specifications
Indications for use
DHS Locking Plate is intended for use in fixation of fractures to the proximal femur. The system is indicated for use in trochanteric, pertrochanteric, intertrochanteric, and basilar neck fracture.
| Holes | 130° | 135° | 140° | 145° | 150° | 135°
Short Barrel |
| 2 | 3-142-02 | 3-144-02 | 3-146-02 | 3-148-02 | 3-150-02 | 3-152-02 |
| 3 | 3-142-03 | 3-144-03 | 3-146-03 | 3-148-03 | 3-150-03 | 3-152-03 |
| 4 | 3-142-04 | 3-144-04 | 3-146-04 | 3-148-04 | 3-150-04 | 3-152-04 |
| 5 | 3-142-05 | 3-144-05 | 3-146-05 | 3-148-05 | 3-150-05 | 3-152-05 |
| 6 | 3-142-06 | 3-144-06 | 3-146-06 | 3-148-06 | 3-150-06 | 3-152-06 |
| 7 | 3-142-07 | 3-144-07 | 3-146-07 | 3-148-07 | 3-150-07 | 3-152-07 |
| 8 | 3-142-08 | 3-144-08 | 3-146-08 | 3-148-08 | 3-150-08 | 3-152-08 |
| 9 | 3-142-09 | 3-144-09 | 3-146-09 | 3-148-09 | 3-150-09 | 3-152-09 |
| 10 | 3-142-10 | 3-144-10 | 3-146-10 | 3-148-10 | 3-150-10 | 3-152-10 |
| 12 | 3-142-12 | 3-144-12 | 3-146-12 | 3-148-12 | 3-150-12 | 3-152-12 |
| 14 | 3-142-14 | 3-144-14 | 3-146-14 | 3-148-14 | 3-150-14 | 3-152-14 |
| 16 | 3-142-16 | 3-144-16 | 3-146-16 | 3-148-16 | 3-150-16 | 3-152-16 |
| 18 | 3-142-18 | 3-144-18 | 3-146-18 | 3-148-18 | 3-150-18 | 3-152-18 |
| 20 | 3-142-20 | 3-144-20 | 3-146-20 | 3-148-20 | 3-150-20 | 3-152-20 |
| 22 | 3-142-22 | 3-144-22 | 3-146-22 | 3-148-22 | 3-150-22 | 3-152-22 |
A DHS Locking Plate is an orthopedic fixation device designed for stabilizing fractures of the proximal femur. It is intended for specific fracture patterns around the upper femur, including trochanteric, pertrochanteric, intertrochanteric, and basilar neck fractures.
The DHS Locking Plate is available in both titanium and stainless steel, allowing healthcare professionals to select the appropriate material according to the clinical and surgical requirements.
The plate features locking compression holes and round locking holes designed to accept 4.5 mm and 5.0 mm cortical and locking screws.
The DHS Locking Plate is offered in several configurations, including 130°, 135°, 140°, 145°, and 150°, as well as a 135° short barrel option.
The plate is available in multiple hole configurations, ranging from 2 to 22 holes, including 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, and 22 holes.