Thompson Hip Prothesis, Standard Stem, Regular Finish

Thompson Hip Prothesis, Standard Stem, Regular Finish

Specifications
• Fixature Type: Cemented.
• Stem is thickened at one end while tapered at the other. This feature of the stem
prevents its rotation once implanted.
• Collar are meant for weight distribution on the calcar. Also it has positive impact on
micro-motions and additionally prevents osteopenia.
• In standard prosthesis, collar between the stem and neck minimize the migration of
polyethlene wear debris.
• It is available in different head sizes which enables it to fit accurately in the
acetabulum. Head dia varies from 37-55mm.
• Available in both sterile and non-sterile form.
Indications for use
It is indicated for:
• Replacement of the degenerated femoral head
• Femoral neck fractures
• Idiopathic avascular necrosis
• Nonunions
Gamma Sterilization can be down on request (Minimum Quantity 20Pcs assorted sizes)

Product Specifications

Specifications
• Fixature Type: Cemented.
• Stem is thickened at one end while tapered at the other. This feature of the stem
prevents its rotation once implanted.
• Collar are meant for weight distribution on the calcar. Also it has positive impact on
micro-motions and additionally prevents osteopenia.
• In standard prosthesis, collar between the stem and neck minimize the migration of
polyethlene wear debris.
• It is available in different head sizes which enables it to fit accurately in the
acetabulum. Head dia varies from 37-55mm.
• Available in both sterile and non-sterile form.
Indications for use
It is indicated for:
• Replacement of the degenerated femoral head
• Femoral neck fractures
• Idiopathic avascular necrosis
• Nonunions
Gamma Sterilization can be down on request (Minimum Quantity 20Pcs assorted sizes)

Head Dia (mm) Sterile Non-Sterile
37 8-200-37 8-300-37
38 8-200-38 8-300-38
39 8-200-39 8-300-39
40 8-200-40 8-300-40
41 8-200-41 8-300-41
42 8-200-42 8-300-42
43 8-200-43 8-300-43
44 8-200-44 8-300-44
45 8-200-45 8-300-45
46 8-200-46 8-300-46
47 8-200-47 8-300-47
48 8-200-48 8-300-48
49 8-200-49 8-300-49
50 8-200-50 8-300-50
51 8-200-51 8-300-51
52 8-200-52 8-300-52
53 8-200-53 8-300-53
54 8-200-54 8-300-54
55 8-200-55 8-300-55

 