Specifications
Indications for use
Locking Metaphyseal Plate for distal medial tibia is a preshaped plate that allows optimal treatment of juxta-articular fractures of the distal tibia extending into the shaft area.This plate takes the following characteristics of the distal tibia into account:
– Thin, soft tissue coverage
– Complex anatomic shape of the bone
Specifications
Indications for use
Locking Metaphyseal Plate for distal medial tibia is a preshaped plate that allows optimal treatment of juxta-articular fractures of the distal tibia extending into the shaft area.This plate takes the following characteristics of the distal tibia into account:
– Thin, soft tissue coverage
– Complex anatomic shape of the bone
| Holes | Stainless Steel
(Right) |
Titanium (Right) | Stainless Steel
(Left) |
Titanium (Left) |
| 4 + 4 | 2-118-04R | 2-118-04R-Ti | 2-118-04L | 2-118-04L-Ti |
| 4 + 5 | 2-118-05R | 2-118-05R-Ti | 2-118-05L | 2-118-05L-Ti |
| 4 + 6 | 2-118-06R | 2-118-06R-Ti | 2-118-06L | 2-118-06L-Ti |
| 4 + 7 | 2-118-07R | 2-118-07R-Ti | 2-118-07L | 2-118-07L-Ti |
| 4 + 8 | 2-118-08R | 2-118-08R-Ti | 2-118-08L | 2-118-08L-Ti |
| 4 + 9 | 2-118-09R | 2-118-09R-Ti | 2-118-09L | 2-118-09L-Ti |
| 4 + 10 | 2-118-10R | 2-118-10R-Ti | 2-118-10L | 2-118-10L-Ti |
| 4 + 12 | 2-118-12R | 2-118-12R-Ti | 2-118-12L | 2-118-12L-Ti |
| 4 + 14 | 2-118-14R | 2-118-14R-Ti | 2-118-14L | 2-118-14L-Ti |
| 4 + 16 | 2-118-16R | 2-118-16R-Ti | 2-118-16L | 2-118-16L-Ti |
| 4 + 18 | 2-118-18R | 2-118-18R-Ti | 2-118-18L | 2-118-18L-Ti |
| 4 + 20 | 2-118-20R | 2-118-20R-Ti | 2-118-20L | 2-118-20L-Ti |
The 3.5mm Locking Metaphyseal Plate for Medial Distal Tibia is a pre shaped orthopedic plate designed for fixation of juxta articular fractures of the distal tibia that extend into the shaft area.
The plate features locking compression holes and round locking holes that are designed to accept 3.5mm cortical and locking screws.
Yes. The plate is available in right and left configurations, allowing selection according to the affected side and surgical requirements.
The 3.5mm Locking Metaphyseal Plate is available in both titanium and stainless steel options. The appropriate material should be selected according to the surgeon's clinical requirements and applicable device specifications.
The plate is available in multiple hole configurations, including 4+4, 4+5, 4+6, 4+7, 4+8, 4+9, 4+10, 4+12, 4+14, 4+16, 4+18, and 4+20 holes, providing different options for fracture fixation requirements.