2.7mm X Locking Plate in titanium. Available with 4 holes and four listed dimensional options: 22 x 14mm, 24 x 18mm, 30 x 20mm and 36 x 20mm. Supports 2.4mm or 2.7mm locking screws. View the catalogue references below.
2.7mm X Locking Plate is part of the StahlmannPro 2.7mm Foot System catalogue. This X plate also accepts the stated 2.4mm locking screw option. The titanium plate is listed with 4 holes and four listed dimensional options: 22 x 14mm, 24 x 18mm, 30 x 20mm and 36 x 20mm. The catalogue specifies support for 2.4mm or 2.7mm locking screws. Use the size table to identify the exact configuration for your enquiry.
The catalogue describes a low-profile, contourable design. Dots identify locking holes with converging screw trajectories. Follow the device instructions for contouring limits.
When reviewing the 2.7mm X Locking Plate, compare the listed hole arrangement and dimensions together. A shared system diameter does not establish compatibility with components from another system. Confirm the exact plate, screw and instrument combination in the current device documentation.
The catalogue lists fixation of fractures, osteotomies, nonunions and fusions of small bones and small bone fragments of the foot. These statements describe the supplied product literature. Suitability for an individual patient must be assessed by the treating surgeon using the current device instructions.
| Holes | Length (mm) | Titanium |
|---|---|---|
| 4 | 22 x 14mm | 4-512-01Ti |
| 4 | 24 x 18mm | 4-512-02Ti |
| 4 | 30 x 20mm | 4-512-03Ti |
| 4 | 36 x 20mm | 4-512-04Ti |
To request the 2.7mm X Locking Plate, provide the full catalogue reference, required quantity and delivery destination. Include the selected configuration and any left or right designation so the quotation can be checked against your specification.
Where your purchasing process requires material grade, packaging condition, sterility information or supporting documentation, request confirmation for the exact reference. These details are not established by the catalogue image. Include any instrument requirements as separate enquiry items.
The catalogue lists 4 holes and four listed dimensional options: 22 x 14mm, 24 x 18mm, 30 x 20mm and 36 x 20mm. Each configuration and its titanium reference appear in the product table.
The supplied page specifies 2.4mm or 2.7mm locking screws. Confirm the complete component combination and required instruments in the applicable device documentation.
The catalogue lists fixation of fractures, osteotomies, nonunions and fusions of small bones and small bone fragments of the foot. The treating surgeon must confirm the intended use and suitability for each case.
The catalogue states that dots identify locking holes with converging screw trajectories. The plate is described as contourable; contouring must follow the applicable device instructions.