WHX Miami 2026 "June 17–19, 2026 Miami Beach Convention Center, USA"
EUROSPINE 2026 "October 7–9, 2026 Gothia Towers & Svenska Mässan, Gothenburg, Sweden"
MEDICA 2026 "November 16–19, 2026 Messe Düsseldorf, Germany"
WHX Dubai 2027 "January 25–28, 2027 Dubai Exhibition Centre, UAE"
AAOS 2027 "March 3–6, 2027 Venetian Convention & Expo Center, Las Vegas, Nevada, USA"
WHX Miami 2026 "June 17–19, 2026 Miami Beach Convention Center, USA"
EUROSPINE 2026 "October 7–9, 2026 Gothia Towers & Svenska Mässan, Gothenburg, Sweden"
MEDICA 2026 "November 16–19, 2026 Messe Düsseldorf, Germany"
WHX Dubai 2027 "January 25–28, 2027 Dubai Exhibition Centre, UAE"
AAOS 2027 "March 3–6, 2027 Venetian Convention & Expo Center, Las Vegas, Nevada, USA"
2.7mm L Locking Plate, Oblique in titanium. Available with left and right versions with 3 or 4 shaft holes, 2 head holes and lengths of 34.6mm or 42.1mm. Supports 2.7mm cortical and locking screws. View the catalogue references below.
2.7mm L Locking Plate, Oblique is part of the StahlmannPro 2.7mm Foot System catalogue. The titanium plate is listed with left and right versions with 3 or 4 shaft holes, 2 head holes and lengths of 34.6mm or 42.1mm. It features compression and locking holes. The catalogue specifies support for 2.7mm cortical and locking screws. Use the size table to identify the exact configuration for your enquiry.
The oblique L design uses the 4-506 series. Its dimensions differ from those of the 4-508 L Locking Plate, so identify the oblique version explicitly.
When reviewing the 2.7mm L Locking Plate, Oblique, compare the listed hole arrangement and dimensions together. A shared system diameter does not establish compatibility with components from another system. Confirm the exact plate, screw and instrument combination in the current device documentation.
The catalogue lists dorsally displaced distal tibial fractures, combined distal tibial with tarsal and metatarsal fractures, and corrective osteotomies. These statements describe the supplied product literature. Suitability for an individual patient must be assessed by the treating surgeon using the current device instructions.
| Type | Holes | Length (mm) | Titanium |
|---|---|---|---|
| Left | Shaft 3, Head 2 | 34.6 | 4-506-03L-Ti |
| Right | Shaft 3, Head 2 | 34.6 | 4-506-03R-Ti |
| Left | Shaft 4, Head 2 | 42.1 | 4-506-04L-Ti |
| Right | Shaft 4, Head 2 | 42.1 | 4-506-04R-Ti |
To request the 2.7mm L Locking Plate, Oblique, provide the full catalogue reference, required quantity and delivery destination. Include the selected configuration and any left or right designation so the quotation can be checked against your specification.
Where your purchasing process requires material grade, packaging condition, sterility information or supporting documentation, request confirmation for the exact reference. These details are not established by the catalogue image. Include any instrument requirements as separate enquiry items.
The catalogue lists left and right versions with 3 or 4 shaft holes, 2 head holes and lengths of 34.6mm or 42.1mm. Each configuration and its titanium reference appear in the product table.
The supplied page specifies 2.7mm cortical and locking screws. Confirm the complete component combination and required instruments in the applicable device documentation.
The catalogue lists dorsally displaced distal tibial fractures, combined distal tibial with tarsal and metatarsal fractures, and corrective osteotomies. The treating surgeon must confirm the intended use and suitability for each case.
The 3-shaft-hole versions are 4-506-03L-Ti and 4-506-03R-Ti. The 4-shaft-hole versions are 4-506-04L-Ti and 4-506-04R-Ti. L and R distinguish the listed sides.
Send the full product name, catalogue reference, configuration and side where applicable, quantity per item and delivery destination. Include any required packaging or product documentation.