Specifications
Indications for use
Specifications
Indications for use
| Length (mm) | Stainless Steel | Titanium |
| 25 | 3-430-25 | 3-430-25Ti |
| 30 | 3-430-30 | 3-430-30Ti |
| 35 | 3-430-35 | 3-430-35Ti |
| 40 | 3-430-40 | 3-430-40Ti |
| 45 | 3-430-45 | 3-430-45Ti |
| 50 | 3-430-50 | 3-430-50Ti |
| 55 | 3-430-55 | 3-430-55Ti |
| 60 | 3-430-60 | 3-430-60Ti |
| 65 | 3-430-65 | 3-430-65Ti |
| 70 | 3-430-70 | 3-430-70Ti |
| 75 | 3-430-75 | 3-430-75Ti |
| 80 | 3-430-80 | 3-430-80Ti |
| 85 | 3-430-85 | 3-430-85Ti |
| 90 | 3-430-90 | 3-430-90Ti |
| 95 | 3-430-95 | 3-430-95Ti |
| 100 | 3-430-100 | 3-430-100Ti |
| 105 | 3-430-105 | 3-430-105Ti |
| 110 | 3-430-110 | 3-430-110Ti |
| 115 | 3-430-115 | 3-430-115Ti |
| 120 | 3-430-120 | 3-430-120Ti |
6.5mm Cancellous Bone Screws are designed for fracture fixation and stabilization in areas of bone with cancellous or softer bone structure. Their threaded design helps provide secure fixation when used appropriately.
The 16mm thread specification refers to the threaded portion of the screw. This configuration is designed to provide appropriate purchase within cancellous bone while allowing the screw to achieve the intended fixation.
These screws have a nominal diameter of 6.5mm, making them suitable for orthopedic fixation applications where a larger cancellous screw is required.
Selection should be based on the fracture type, bone quality, anatomical location, required fixation strength, and the surgical technique being used. Qualified orthopedic professionals should determine the appropriate screw size and configuration.
They may be used in various orthopedic fixation procedures involving cancellous bone, depending on the specific surgical indication and compatible fixation system. Their use should always follow the manufacturer's specifications and the surgeon's clinical judgment.