Specification
Indications for use
Specification
Indications for use
| Holes | Right Stainless Steel | Right Titanium | Left Stainless Steel | Left Titanium |
| 5 | 2-132-05R | 2-132-05R-Ti | 2-132-05L | 2-132-05L-Ti |
| 7 | 2-132-07R | 2-132-07R-Ti | 2-132-07L | 2-132-07L-Ti |
| 9 | 2-132-09R | 2-132-09R-Ti | 2-132-09L | 2-132-09L-Ti |
| 11 | 2-132-11R | 2-132-11R-Ti | 2-132-11L | 2-132-11L-Ti |
| 13 | 2-132-13R | 2-132-13R-Ti | 2-132-13L | 2-132-13L-Ti |
| 15 | 2-132-15R | 2-132-15R-Ti | 2-132-15L | 2-132-15L-Ti |
| 17 | 2-132-17R | 2-132-17R-Ti | 2-132-17L | 2-132-17L-Ti |
| 19 | 2-132-19R | 2-132-19R-Ti | 2-132-19L | 2-132-19L-Ti |
| 21 | 2-132-21R | 2-132-21R-Ti | 2-132-21L | 2-132-21L-Ti |
The 3.5mm Locking Anterolateral Distal Tibia Plate is designed for fixation of extra articular and simple intra articular distal tibia fractures. It can also be used for distal tibia fractures extending into the diaphyseal area.
The plate features locking compression holes and round locking holes that accept 3.5mm cortical and locking screws. The plate head can also accommodate 2.7mm cortex screws where appropriate.
Yes. The plate is available in both titanium and stainless steel options. Right and left sided versions are also available to accommodate the required surgical application.
The 3.5mm Locking Anterolateral Distal Tibia Plate is available with 5, 7, 9, 11, 13, 15, 17, 19, and 21 holes, allowing surgeons to select a suitable plate length based on the fracture pattern and fixation requirements.
The plate includes angled distal head holes, an elongated positioning hole, distal locking screw support for the articular surface, and a contoured shaft designed to follow distal tibia anatomy. Its low profile is intended to help reduce soft tissue irritation.