12.5mm DHS / DCS Screw (With Compression Screw)

12.5mm DHS / DCS Screw (With Compression Screw)

Specifications

  • Available in 50 mm to 145 mm length with 12.5 mm diameter.
  • Partially threaded shaft.
  • Available in both Titanium and stainless steel.

Indications for use

It is used in the fixation of Large Fragment Locking Plates.

Product Specifications

Specifications

  • Available in 50 mm to 145 mm length with 12.5 mm diameter.
  • Partially threaded shaft.
  • Available in both Titanium and stainless steel.

Indications for use

It is used in the fixation of Large Fragment Locking Plates.

Length (mm) Stainless Steel Titanium
50 6-200-50 6-200-50Ti
55 6-200-55 6-200-55Ti
60 6-200-60 6-200-60Ti
65 6-200-65 6-200-65Ti
70 6-200-70 6-200-70Ti
75 6-200-75 6-200-75Ti
80 6-200-80 6-200-80Ti
85 6-200-85 6-200-85Ti
90 6-200-90 6-200-90Ti
95 6-200-95 6-200-95Ti
100 6-200-100 6-200-100Ti
105 6-200-105 6-200-105Ti
110 6-200-110 6-200-110Ti
115 6-200-115 6-200-115Ti
120 6-200-120 6-200-120Ti
125 6-200-125 6-200-125Ti
130 6-200-130 6-200-130Ti
135 6-200-135 6-200-135Ti
140 6-200-140 6-200-140Ti
145 6-200-145 6-200-145Ti

FAQs

What is a 12.5mm DHS DCS Screw with Compression Screw?

A 12.5mm DHS DCS Screw with Compression Screw is an orthopedic fixation component designed for use with compatible dynamic hip screw and dynamic condylar screw systems. It supports controlled compression and stabilization during fracture fixation procedures.

What is the purpose of the compression screw?

The compression screw is used to help maintain the position of the main screw and facilitate controlled compression of the fracture site when used with a compatible fixation construct.

What procedures are DHS and DCS screws commonly used for?

DHS and DCS systems are commonly used in orthopedic fracture fixation, particularly for selected fractures involving the proximal femur and distal femur. The appropriate fixation method depends on fracture pattern and surgical assessment.

Is the 12.5mm DHS DCS Screw compatible with all fixation systems?

Compatibility depends on the implant system, dimensions, thread specifications, and instrumentation being used. Surgeons and medical professionals should verify compatibility with the manufacturer's specifications before use.

What material is used for the 12.5mm DHS DCS Screw?

The exact material and material grade should be confirmed from the product specifications or technical documentation provided by the manufacturer. Material selection is important for implant strength, biocompatibility, and clinical performance.