Specifications
Indication for use
It is used to fix fractures and non-unions of the fibula, Distal tibia, Pelvis, Ulna, Radius, Humerous, Olecranon, Scapula & Clavicle.
Specifications
Indication for use
It is used to fix fractures and non-unions of the fibula, Distal tibia, Pelvis, Ulna, Radius, Humerous, Olecranon, Scapula & Clavicle.
| Holes | Stainless Steel | Titanium |
| 2 | 2-306-02 | 2-306-02Ti |
| 3 | 2-306-03 | 2-306-03Ti |
| 4 | 2-306-04 | 2-306-04Ti |
| 5 | 2-306-05 | 2-306-05Ti |
| 6 | 2-306-06 | 2-306-06Ti |
| 7 | 2-306-07 | 2-306-07Ti |
| 8 | 2-306-08 | 2-306-08Ti |
| 9 | 2-306-09 | 2-306-09Ti |
| 10 | 2-306-10 | 2-306-10Ti |
| 11 | 2-306-11 | 2-306-11Ti |
| 12 | 2-306-12 | 2-306-12Ti |
| 13 | 2-306-13 | 2-306-13Ti |
| 14 | 2-306-14 | 2-306-14Ti |
The 3.5mm DCP Dynamic Compression Plate is an orthopedic fixation plate designed to stabilize fractures and non unions. Its oval shaped holes help create dynamic compression between fractured bone fragments during fixation.
The 3.5mm DCP Dynamic Compression Plate is available in both stainless steel and titanium options, allowing healthcare professionals to select the appropriate material according to the surgical requirements.
All holes in the plate are designed to support 3.5mm cortical screws and 4.0mm cancellous screws. The appropriate screw type should be selected by a qualified orthopedic professional based on the fracture and fixation requirements.
The plate is indicated for fixation of fractures and non unions involving areas such as the fibula, distal tibia, pelvis, ulna, radius, humerus, olecranon, scapula, and clavicle.
The 3.5mm DCP Dynamic Compression Plate is available with 2 through 14 holes. Different hole configurations provide options for surgeons to select a plate length appropriate for the intended fixation procedure.