1.5mm Adaption T Locking Plate

1.5mm Adaption T Locking Plate

1.5mm Adaption T Locking Plate in titanium with 8 shaft holes and a choice of 3 or 4 head holes. Both versions measure 44.5 mm and support 1.5mm cortical and locking screws in all holes.

Product Specifications

1.5mm Adaption T Locking Plate is available in two titanium configurations, each with 8 shaft holes and a 44.5 mm length. The choice is between 3 and 4 head holes, with a separate catalogue reference for each version.

This titanium T locking plate sits within the StahlmannPro 1.5mm Hand System. All holes support 1.5mm cortical and locking screws. When comparing this hand fracture fixation plate, check the head-hole configuration as well as the length, since the length remains the same for both options.

Specifications

  • Titanium plate.
  • 8 shaft holes in both versions.
  • Choice of 3 or 4 head holes.
  • 44.5 mm length.
  • Compatibility with 1.5mm cortical and locking screws in every hole.

Indications for Use

The catalogue lists proximal and distal extra-articular, partial articular and complete articular fractures of the hand.

Sizes and Product References

Holes Length (mm) Titanium
Shaft 8, Head 3 44.5 4-204-03Ti
Shaft 8, Head 4 44.5 4-204-04Ti

Ordering Information

State whether you require the 3 or 4 head hole plate. Reference 4-204-03Ti identifies the 3-head-hole model, while 4-204-04Ti identifies the 4-head-hole model. Use the table to match the requested configuration before sending an enquiry.

FAQs

What applications are listed for the 1.5mm Adaption T Locking Plate?

The catalogue lists proximal and distal extra-articular, partial articular and complete articular fractures of the hand. The surgical team must confirm the appropriate plate configuration for the individual case.

What sizes and hole configurations are available?

Both titanium versions measure 44.5 mm and have 8 shaft holes. Buyers can choose between 3 head holes and 4 head holes, each identified by a separate catalogue reference.

Which screws does the Adaption T Locking Plate accept?

The catalogue states that all holes support 1.5mm cortical and locking screws. Confirm the required screws and compatible instruments as part of the complete system specification.

What are the product codes for the two configurations?

The version with 8 shaft holes and 3 head holes uses reference 4-204-03Ti. The version with 8 shaft holes and 4 head holes uses 4-204-04Ti.

What should I specify when requesting an Adaption T plate?

State whether you require 3 or 4 head holes, then include the corresponding product code and quantity. Specifying the 44.5 mm length alone will not distinguish the two versions.