Join Stahlmann Pro at AAOS 2026 in New Orleans. Booth 826.

3.5mm Locking Anterolateral Distal Tibia Plate

3.5mm Locking Anterolateral Distal Tibia Plate

Specification

  • Plates(Right & Left) available in both-Titanium & Stainless steel.
  • Plate features locking compression holes and round locking holes that accepts 3.5mm cortical and locking screws.
  • Four distal head holes angle 7° inferiorly to capture the posterior malleolus.
  • Elongated hole aids in plate positioning
  • Distal locking screws provide support for the articular surface..
  • Targeted locking for Volkman’s triangle and the Chaput fragment.
  • The head of the plate is designed to provide a low profile construct when using locking screws or cortex screws Ø 2.7 mm, resulting in less soft tissue irritation.
  • 60°twist in the shaft is contoured for the distal tibia anatomy: less plate contouring is required.
  • Plate available with 5,7,9,11,13,15,17,19, & 21 holes

 

Indications for use

  • Extra-articular and simple intra-articular distal tibia fractures
  • Distal tibia fracture, percutaneous or reducible by limited arthrotomy
  • Distal tibia fracture extending into the diaphyseal area

Product Specifications

Specification

  • Plates(Right & Left) available in both-Titanium & Stainless steel.
  • Plate features locking compression holes and round locking holes that accepts 3.5mm cortical and locking screws.
  • Four distal head holes angle 7° inferiorly to capture the posterior malleolus.
  • Elongated hole aids in plate positioning
  • Distal locking screws provide support for the articular surface..
  • Targeted locking for Volkman’s triangle and the Chaput fragment.
  • The head of the plate is designed to provide a low profile construct when using locking screws or cortex screws Ø 2.7 mm, resulting in less soft tissue irritation.
  • 60°twist in the shaft is contoured for the distal tibia anatomy: less plate contouring is required.
  • Plate available with 5,7,9,11,13,15,17,19, & 21 holes

 

Indications for use

  • Extra-articular and simple intra-articular distal tibia fractures
  • Distal tibia fracture, percutaneous or reducible by limited arthrotomy
  • Distal tibia fracture extending into the diaphyseal area
Holes Right Stainless Steel Right Titanium Left Stainless Steel Left Titanium
5 2-132-05R 2-132-05R-Ti 2-132-05L 2-132-05L-Ti
7 2-132-07R 2-132-07R-Ti 2-132-07L 2-132-07L-Ti
9 2-132-09R 2-132-09R-Ti 2-132-09L 2-132-09L-Ti
11 2-132-11R 2-132-11R-Ti 2-132-11L 2-132-11L-Ti
13 2-132-13R 2-132-13R-Ti 2-132-13L 2-132-13L-Ti
15 2-132-15R 2-132-15R-Ti 2-132-15L 2-132-15L-Ti
17 2-132-17R 2-132-17R-Ti 2-132-17L 2-132-17L-Ti
19 2-132-19R 2-132-19R-Ti 2-132-19L 2-132-19L-Ti
21 2-132-21R 2-132-21R-Ti 2-132-21L 2-132-21L-Ti

Related products